Literature DB >> 18375327

Assessment of fluid-responsiveness parameters for off-pump coronary artery bypass surgery: a comparison among LiDCO, transesophageal echochardiography, and pulmonary artery catheter.

Luigi Belloni1, Antonio Pisano, Armando Natale, Maria Rosario Piccirillo, Luigi Piazza, Gennaro Ismeno, Giovanni De Martino.   

Abstract

OBJECTIVE: To verify the reliability of different markers of fluid-responsiveness during off-pump cardiac surgery (OPCAB).
DESIGN: A clinical prospective, nonblinded, nonrandomized study.
SETTING: A community hospital. PARTICIPANTS: Nineteen patients.
INTERVENTIONS: Pulmonary artery catheter (PAC), LiDCO (LiDCO, London, UK), and transesophageal echocardiography (TEE) parameters were measured before (t0) and after (t1) a fluid challenge was performed 20 minutes after induction of anesthesia, but before sternotomy and without inotropic infusion. A Student t test and Spearman test were performed for statistical analysis.
MEASUREMENTS AND MAIN RESULTS: According to the variation of cardiac index after the fluid challenge (DeltaCI%), 2 groups of patients were identified: the responders (Re, DeltaCI% > 15%) and the nonresponders (nRe). Mean pulse pressure variation (PPV) and mean stroke volume variation (SVV) before the fluid challenge (t0) were significantly different between the 2 groups. No significant differences were shown in systolic pressure variation (SPV), left ventricular end-diastolic area, left ventricular end-diastolic volume, and peak changes of aortic flow (DeltaVAo). A statistically significant correlation was observed between DeltaCI% and PPV (R = 0.793), DeltaCI% and SVV (R = 0.809), and DeltaCI% and SPV (R = 0.766). No correlation with central venous pressure and pulmonary capillary wedge pressure was found.
CONCLUSIONS: Dynamic parameters of fluid responsiveness by LiDCO are highly sensitive for assessment of intravascular volume status during OPCAB surgery. In contrast, even if static parameters by TEE reflect changes in ventricular diastolic volume, they are poor indicators of fluid responsiveness. Surprisingly, no significant correlation between DeltaVAo (TEE) and DeltaCI% was found.

Entities:  

Mesh:

Year:  2007        PMID: 18375327     DOI: 10.1053/j.jvca.2007.07.007

Source DB:  PubMed          Journal:  J Cardiothorac Vasc Anesth        ISSN: 1053-0770            Impact factor:   2.628


  19 in total

Review 1.  Minimally invasive or noninvasive cardiac output measurement: an update.

Authors:  Lisa Sangkum; Geoffrey L Liu; Ling Yu; Hong Yan; Alan D Kaye; Henry Liu
Journal:  J Anesth       Date:  2016-03-09       Impact factor: 2.078

Review 2.  Pulse waveform hemodynamic monitoring devices: recent advances and the place in goal-directed therapy in cardiac surgical patients.

Authors:  Adham Hendy; Şerban Bubenek
Journal:  Rom J Anaesth Intensive Care       Date:  2016-04

Review 3.  Using what you get: dynamic physiologic signatures of critical illness.

Authors:  Andre L Holder; Gilles Clermont
Journal:  Crit Care Clin       Date:  2015-01       Impact factor: 3.598

Review 4.  Accuracy of stroke volume variation in predicting fluid responsiveness: a systematic review and meta-analysis.

Authors:  Zhongheng Zhang; Baolong Lu; Xiaoyan Sheng; Ni Jin
Journal:  J Anesth       Date:  2011-09-04       Impact factor: 2.078

Review 5.  Systematic review including re-analyses of 1148 individual data sets of central venous pressure as a predictor of fluid responsiveness.

Authors:  T G Eskesen; M Wetterslev; A Perner
Journal:  Intensive Care Med       Date:  2015-12-09       Impact factor: 17.440

6.  Ability of pulse power, esophageal Doppler, and arterial pulse pressure to estimate rapid changes in stroke volume in humans.

Authors:  José Marquez; Kenneth McCurry; Donald A Severyn; Michael R Pinsky
Journal:  Crit Care Med       Date:  2008-11       Impact factor: 7.598

7.  Recent advance in patient monitoring.

Authors:  Tomoki Nishiyama
Journal:  Korean J Anesthesiol       Date:  2010-09-20

8.  The critically ill obstetric patient - Recent concepts.

Authors:  Anjan Trikha; Pm Singh
Journal:  Indian J Anaesth       Date:  2010-09

Review 9.  Prevention of lung injury in cardiac surgery: a review.

Authors:  Robert W Young
Journal:  J Extra Corpor Technol       Date:  2014-06

Review 10.  The role of transesophageal echocardiography in the intraoperative period.

Authors:  Veronica Gouveia; Paulo Marcelino; Daniel A Reuter
Journal:  Curr Cardiol Rev       Date:  2011-08
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.