Literature DB >> 18374489

Effects of amorphous layers on ADF-STEM imaging.

K A Mkhoyan1, S E Maccagnano-Zacher, E J Kirkland, J Silcox.   

Abstract

A study of high-resolution ADF imaging in uncorrected and aberration-corrected STEMs was carried out by multislice simulation. The presence of amorphous layers at the surface of a crystalline specimen is shown to significantly alter the visibility of the atomic columns. After propagating through an amorphous layer a portion of the beam passes without any alteration while scattered electrons introduce a Gaussian background. The dependence of the image contrast on the crystal structure, orientation and the types of the atoms present in the crystal was studied. In the case of uncorrected probes an amorphous layer thicker than 200 A is necessary to achieve considerable reduction of the visibility of the atomic columns, but with aberration-corrected probes only 60 A is necessary. With changes in defocus, crystalline specimens with amorphous layers on the top can also be imaged and high-resolution ADF images can be obtained. An amorphous layer at the beam entry surface affects the ADF image more than that of an amorphous layer at the exit surface. Approximately linear reduction of the contrast (with a slop of 1) is expected with increased thickness of amorphous layer.

Entities:  

Year:  2008        PMID: 18374489     DOI: 10.1016/j.ultramic.2008.01.007

Source DB:  PubMed          Journal:  Ultramicroscopy        ISSN: 0304-3991            Impact factor:   2.689


  4 in total

1.  Extreme mobility enhancement of two-dimensional electron gases at oxide interfaces by charge-transfer-induced modulation doping.

Authors:  Y Z Chen; F Trier; T Wijnands; R J Green; N Gauquelin; R Egoavil; D V Christensen; G Koster; M Huijben; N Bovet; S Macke; F He; R Sutarto; N H Andersen; J A Sulpizio; M Honig; G E D K Prawiroatmodjo; T S Jespersen; S Linderoth; S Ilani; J Verbeeck; G Van Tendeloo; G Rijnders; G A Sawatzky; N Pryds
Journal:  Nat Mater       Date:  2015-06-01       Impact factor: 43.841

2.  Dose-rate-dependent damage of cerium dioxide in the scanning transmission electron microscope.

Authors:  Aaron C Johnston-Peck; Joseph S DuChene; Alan D Roberts; Wei David Wei; Andrew A Herzing
Journal:  Ultramicroscopy       Date:  2016-07-06       Impact factor: 2.689

3.  Simulating realistic imaging conditions for in situ liquid microscopy.

Authors:  David A Welch; Roland Faller; James E Evans; Nigel D Browning
Journal:  Ultramicroscopy       Date:  2013-05-27       Impact factor: 2.689

4.  Microstructure characterization of BaSnO3 thin films on LaAlO3 and PrScO3 substrates from transmission electron microscopy.

Authors:  Hwanhui Yun; Koustav Ganguly; William Postiglione; Bharat Jalan; Chris Leighton; K Andre Mkhoyan; Jong Seok Jeong
Journal:  Sci Rep       Date:  2018-07-06       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.