OBJECTIVE: Neo-aortic insufficiency (neo-AI) has been noted following the Ross procedure. The purpose of this study was to evaluate the ability of intraoperative transesophageal echocardiography (TEE) to predict future neo-AI in pediatric patients undergoing the Ross from January 1995 to December 2003, who had an intraoperative TEE, and discharge and follow-up transthoracic (TTE) echocardiograms.
DESIGN: Retrospective case series. PATIENTS: All patients who underwent the Ross procedure at Children's Hospital of Philadephia between January 1995 and December 2003, and had an intraoperative TEE, discharge, and follow-up (>6 months) transthoracic echocardiogram (TTE) (by July 1, 2004) were included. OUTCOME MEASURES: Grade of neo-AI was assessed on intraoperative TEE, discharge, and follow-up TTE echocardiogram reports.
RESULTS: Follow-up was available in 99/115 (86%) survivors. Median age at Ross was 9.3 years (4 days-34 years). No patient had more than mild neo-AI on intraoperative TEE. At discharge, 2 patients (2%) had moderate neo-AI. At most recent follow-up (median 4.2 years, 8 months-9.3 years), 21 patients (21%) had moderate or greater neo-AI; 9 underwent neo-aortic reintervention. The presence of any neo-AI on intraoperative TEE had 100% sensitivity and negative predictive value for diagnosing moderate or greater neo-AI at discharge. Patients who had mild neo-AI on TEE were more likely to have moderate or greater neo-AI at most recent follow-up than those patients with no neo-AI on TEE (9% vs. 30%, P = 0.01).
CONCLUSION: Intraoperative TEE is an excellent screening tool for the presence of significant neo-AI at the time of hospital discharge. Neo-AI progresses over time after Ross procedure and is more likely to progress in those patients with neo-AI on intraoperative TEE. However, predictive validity decreases over time as neo-AI progresses.

Entities:  

Mesh:

Year:  2008        PMID: 18373748     DOI: 10.1111/j.1747-0803.2007.00156.x

Source DB:  PubMed          Journal:  Congenit Heart Dis        ISSN: 1747-079X            Impact factor:   2.007


  1 in total

1.  Anesthetic management for severe aortic regurgitation in an infant repaired by Ross procedure.

Authors:  Akira Watabe; Hitoshi Saito; Katsumi Harasawa; Yuji Morimoto
Journal:  J Anesth       Date:  2009-05-15       Impact factor: 2.078

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.