Literature DB >> 18371770

Application of multivariate curve resolution alternating least squares (MCR-ALS) to the quantitative analysis of pharmaceutical and agricultural samples.

T Azzouz1, R Tauler.   

Abstract

Application of multivariate curve resolution alternating least squares (MCR-ALS), for the resolution and quantification of different analytes in different type of pharmaceutical and agricultural samples is shown. In particular, MCR-ALS is applied first to the UV spectrophotometric quantitative analysis of mixtures of commercial steroid drugs, and second to the near-infrared (NIR) spectrophotometric quantitative analysis of humidity and protein contents in forage cereal samples. Quantitative results obtained by MCR-ALS are compared to those obtained using the well established partial least squares regression (PLSR) multivariate calibration method.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18371770     DOI: 10.1016/j.talanta.2007.08.024

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  11 in total

1.  Rapid spontaneous Raman light sheet microscopy using cw-lasers and tunable filters.

Authors:  Israel Rocha-Mendoza; Jacob Licea-Rodriguez; Mónica Marro; Omar E Olarte; Marcos Plata-Sanchez; Pablo Loza-Alvarez
Journal:  Biomed Opt Express       Date:  2015-08-19       Impact factor: 3.732

2.  A continuous flow microfluidic calorimeter: 3-D numerical modeling with aqueous reactants.

Authors:  Mehmet A Sen; Gregory J Kowalski; Jason Fiering; Dale Larson
Journal:  Thermochim Acta       Date:  2015-03-10       Impact factor: 3.115

3.  Application of Multivariate Curve Resolution-Alternate Least Square Technique on Extracting Pure Spectral Components from Multiple Emitting Systems: a Case Study.

Authors:  Madhumita Tarai; Ashok Kumar Mishra
Journal:  J Fluoresc       Date:  2017-07-24       Impact factor: 2.217

4.  Random Initialisation of the Spectral Variables: an Alternate Approach for Initiating Multivariate Curve Resolution Alternating Least Square (MCR-ALS) Analysis.

Authors:  Keshav Kumar
Journal:  J Fluoresc       Date:  2017-06-23       Impact factor: 2.217

5.  Processing Excitation-Emission Matrix Fluorescence and Total Synchronous Fluorescence Spectroscopy Data Sets with Constraint Randomised Non-negative Factor Analysis: a Novel Fluorescence Based Analytical Procedure to Analyse the Multifluorophoric Mixtures.

Authors:  Keshav Kumar
Journal:  J Fluoresc       Date:  2018-08-20       Impact factor: 2.217

6.  Multi-analyte quantification in bioprocesses by Fourier-transform-infrared spectroscopy by partial least squares regression and multivariate curve resolution.

Authors:  Cosima Koch; Andreas E Posch; Héctor C Goicoechea; Christoph Herwig; Bernhard Lendl
Journal:  Anal Chim Acta       Date:  2013-11-11       Impact factor: 6.558

7.  Multivariate Curve Resolution and Carbon Balance Constraint to Unravel FTIR Spectra from Fed-Batch Fermentation Samples.

Authors:  Dennis Vier; Stefan Wambach; Volker Schünemann; Klaus-Uwe Gollmer
Journal:  Bioengineering (Basel)       Date:  2017-01-25

8.  Simultaneous Determination of Drugs Affecting Central Nervous System (CNS) in Bulk and Pharmaceutical Formulations Using Multivariate Curve Resolution-Alternating Least Squares (MCR-ALS).

Authors:  Heba Shaaban; Ahmed Mostafa; Bushra Al-Zahrani; Bushra Al-Jasser; Raghad Al-Ghamdi
Journal:  J Anal Methods Chem       Date:  2020-02-11       Impact factor: 2.193

9.  Eco-friendly multivariate curve resolution-alternating least squares and chromatographic quantifications of some veterinary drug residues in pharmaceutical industrial wastewater.

Authors:  Osama I Abdel Sattar; Hamed H M Abuseada; Mohamed S Emara; Mahmoud Rabee
Journal:  RSC Adv       Date:  2021-01-14       Impact factor: 3.361

10.  Multivariate unmixing approaches on Raman images of plant cell walls: new insights or overinterpretation of results?

Authors:  Batirtze Prats-Mateu; Martin Felhofer; Anna de Juan; Notburga Gierlinger
Journal:  Plant Methods       Date:  2018-07-04       Impact factor: 4.993

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.