Literature DB >> 18371689

Isolation, purification and determination of 4-n-nonylphenol and 4-tert-octylphenol in aqueous and biological samples.

Renata Gadzała-Kopciuch1, Anna Filipiak, Bogusław Buszewski.   

Abstract

The aim of the present study was to attempt to describe the procedure of isolation, purification, enrichment and determination of 4-n-nonylphenol (4-n-NP) and 4-tert-octylphenol (4-t-OP) in water and biological samples (fish tissue). There were five procedures of solid phase extraction (SPE) tested using different sorbents for the isolation of analytes from water samples. Moreover, we isolated these chemicals from biological matrices with the aid of various extraction methods. The purpose of it was to perform an optimisation of ultrasonic bath, accelerated solvent extraction (ASE) and solid phase extraction process of alkylphenols from biological samples, through the choice of selective sorbents (octadecyl, octadecyl end-capped and amine) and search solvents (methylene chloride, methanol, hexane). Reversed-phase HPLC with diode array detection was used for the determination of 4-n-NP and 4-t-OP in water and fish tissue samples. Sensitivity was evaluated by determining the limit of detection (LOD=0.06 and 0.04ng microL(-1)) and limit of quantification (LOQ=0.18 and 0.16ng microL(-1)) of 4-NP and 4-t-OP, respectively. A series of standard solutions for 4-n-NP and 4-t-OP provided the basis for plotting an analytical curve and obtaining a linear dependence in the range of approximately 1-25ng microL(-1). The best efficiencies obtained for 4-n-NP and 4-t-OP in water samples were 76.65% (+/-1.49) and 83.08% (+/-3.73), respectively. In the case of fish tissue, different situation was observed because the obtained values were considerably lower, being 68.32% for 4-t-OP using hexane (program 1) as solvent and 72.35% (program 2) for 4-n-NP using acetonitrile.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18371689     DOI: 10.1016/j.talanta.2007.06.028

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

1.  Determination of three alkylphenol isomers in various water samples using a new HPLC method based on a duet stationary phase.

Authors:  Ioana Cruceru; Andreea Florescu; Irinel Adriana Badea; Luminita Vladescu
Journal:  Environ Monit Assess       Date:  2011-11-10       Impact factor: 2.513

2.  Seasonal and spatial distribution of 4-tert-octylphenol, 4-nonylphenol and bisphenol A in the Huangpu River and its tributaries, Shanghai, China.

Authors:  Minghong Wu; Liang Wang; Gang Xu; Ning Liu; Liang Tang; Jisan Zheng; Tingting Bu; Bingli Lei
Journal:  Environ Monit Assess       Date:  2012-07-22       Impact factor: 2.513

3.  HPLC-FLD determination of 4-nonylphenol and 4-tert-octylphenol in surface water samples.

Authors:  Ioana Cruceru; Vasile Iancu; Jana Petre; Irinel Adriana Badea; Luminita Vladescu
Journal:  Environ Monit Assess       Date:  2011-06-18       Impact factor: 2.513

  3 in total