Literature DB >> 18370947

Hip orthosis powered by pneumatic artificial muscle: voluntary activation in absence of myoelectrical signal.

Breno Gontijo do Nascimento1, Claysson Bruno Santos Vimieiro, Danilo Alves Pinto Nagem, Marcos Pinotti.   

Abstract

Powered orthosis is a special class of gait assist device that employs a mechanical or electromechanical actuator to enhance movement of hip, knee, or ankle articulations. Pneumatic artificial muscle (PAM) has been suggested as a pneumatic actuator because its performance is similar to biological muscle. The electromyography (EMG) signal interpretation is the most popular and simplest method to establish the patient voluntary control of the orthosis. However, this technique is not suitable for patients presenting neurological lesions causing absence or very low quality of EMG signal. For those cases, an alternative control strategy should be provided. The aim of the present study is to develop a gait assistance orthosis for lower limb powered by PAMs controlled by a voluntary activation method based on the angular behavior of hip joint. In the present study, an orthosis that has been molded in a patient was employed and, by taking her anthropometric parameters and movement constraints, the adaptation of the existing orthosis to the powered orthosis was planned. A control system was devised allowing voluntary control of a powered orthosis suitable for patients presenting neurological lesions causing absence or very low quality of EMG signal. A pilot clinical study was reported where a patient, victim of poliovirus, successfully tested a hip orthosis especially modified for the gait test evaluation in the parallel bar system. The hip orthosis design and the control circuitry parameters were able to be set to provide satisfactory and comfortable use of the orthosis during the gait cycle.

Entities:  

Mesh:

Year:  2008        PMID: 18370947     DOI: 10.1111/j.1525-1594.2008.00549.x

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  3 in total

1.  Feasibility of a Hydraulic Power Assist System for Use in Hybrid Neuroprostheses.

Authors:  Kevin M Foglyano; Rudi Kobetic; Curtis S To; Thomas C Bulea; John R Schnellenberger; Musa L Audu; Mark J Nandor; Roger D Quinn; Ronald J Triolo
Journal:  Appl Bionics Biomech       Date:  2015-03-18       Impact factor: 1.781

2.  A pneumatically powered knee-ankle-foot orthosis (KAFO) with myoelectric activation and inhibition.

Authors:  Gregory S Sawicki; Daniel P Ferris
Journal:  J Neuroeng Rehabil       Date:  2009-06-23       Impact factor: 4.262

3.  Biomechanical analysis of an unpowered hip flexion orthosis on individuals with and without multiple sclerosis.

Authors:  Ross M Neuman; Staci M Shearin; Karen J McCain; Nicholas P Fey
Journal:  J Neuroeng Rehabil       Date:  2021-06-27       Impact factor: 4.262

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.