Literature DB >> 18369703

Passive removal of silicone oil with a 25-gauge sutureless system.

Ziya Kapran1, Nur Acar, Yaprak Banu Unver, Tugrul Altan, Bulut Ocak.   

Abstract

PURPOSE: To report the outcome of a new sutureless technique for passive removal of silicone oil with a 25-gauge system.
METHODS: Between January 2005 and February 2006, 32 patients (32 eyes) underwent passive silicone oil removal with a 25-gauge system in a prospective, interventional case series in our hospital. Main data recorded were visual acuity, intraocular pressure (IOP), silicone oil removal time, complications, and number of sutured sites.
RESULTS: Mean follow-up was 11.46 +/- 3.98 months. Mean silicone oil removal time was 8.93 +/- 0.85 (range, 7.0-11.5) min. A suture was placed in only one eye because of leakage. Visual acuity improved in 27 eyes (86.4%), and stabilized in five eyes (15.6%). IOP decreased significantly at all visits during follow-up. On day one, four eyes (12.5%) were hypotonous. Choroidal folds were observed in two eyes (6.25%). No other complications were noted.
CONCLUSIONS: Passive removal of silicone oil with a 25-gauge sutureless technique was effective for 1000 centistokes of oil. Transient hypotony in the early postoperative period did not adversely affect the visual outcomes.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18369703     DOI: 10.1007/s10384-007-0490-x

Source DB:  PubMed          Journal:  Jpn J Ophthalmol        ISSN: 0021-5155            Impact factor:   2.447


  3 in total

1.  25-gauge vs 20-gauge system for pars plana vitrectomy: a prospective randomised clinical trial.

Authors:  Lukas Kellner; Barbara Wimpissinger; Ulrike Stolba; Werner Brannath; Susanne Binder
Journal:  Br J Ophthalmol       Date:  2007-01-03       Impact factor: 4.638

2.  Initial experience using the transconjunctival sutureless vitrectomy system for vitreoretinal surgery.

Authors:  Gildo Y Fujii; Eugene De Juan; Mark S Humayun; Tom S Chang; Dante J Pieramici; Aaron Barnes; David Kent
Journal:  Ophthalmology       Date:  2002-10       Impact factor: 12.079

3.  Silicone oil removal using a self-sealing corneal incision under topical anesthesia.

Authors:  R Yildirim; C Aras; A Ozdamar; H Bahcecioglu
Journal:  Ophthalmic Surg Lasers       Date:  1999-01
  3 in total
  4 in total

1.  Comparison of the silicone oil removal rate between vitrectomy and manual syringe negative pressure approach.

Authors:  Zhong Lin; Rong Han Wu; Ye Hui Zhou
Journal:  Int Ophthalmol       Date:  2016-09-17       Impact factor: 2.031

2.  Efficacy and safety of active silicone oil removal through a 23-gauge transconjunctival cannula using an external vacuum pump.

Authors:  Hyun Ju Oh; Woohyok Chang; Min Sagong
Journal:  Int J Ophthalmol       Date:  2015-04-18       Impact factor: 1.779

3.  Passive Removal of Silicone Oil with Temporal Head Position through Two 23-Gauge Cannulas.

Authors:  Zhong Lin; Zhi Sheng Ke; Qian Zheng; Zhen Quan Zhao; Zong Ming Song
Journal:  J Ophthalmol       Date:  2016-06-22       Impact factor: 1.909

4.  Small gauge vitrectomy: Recent update.

Authors:  Sumeet Khanduja; Ashish Kakkar; Saptrishi Majumdar; Rajpal Vohra; Satpal Garg
Journal:  Oman J Ophthalmol       Date:  2013-01
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.