Literature DB >> 18369280

Prototyping a large field size IORT applicator for a mobile linear accelerator.

Rogier W J Janssen1, Bruce A Faddegon, Wim J F Dries.   

Abstract

The treatment of large tumors such as sarcomas with intra-operative radiotherapy using a Mobetron is often complicated because of the limited field size of the primary collimator and the available applicators (max Ø100 mm). To circumvent this limitation a prototype rectangular applicator of 80 x 150 mm(2) was designed and built featuring an additional scattering foil located at the top of the applicator. Because of its proven accuracy in modeling linear accelerator components the design was based on the EGSnrc Monte Carlo simulation code BEAMnrc. First, the Mobetron treatment head was simulated both without an applicator and with a standard 100 mm applicator. Next, this model was used to design an applicator foil consisting of a rectangular Al base plate covering the whole beam and a pyramid of four stacked cylindrical slabs of different diameters centered on top of it. This foil was mounted on top of a plain rectangular Al tube. A prototype was built and tested with diode dosimetry in a water tank. Here, the prototype showed clinically acceptable 80 x 150 mm(2) dose distributions for 4 MeV, 6 MeV and 9 MeV, obviating the use of complicated multiple irradiations with abutting field techniques. In addition, the measurements agreed well with the MC simulations, typically within 2%/1 mm.

Entities:  

Mesh:

Year:  2008        PMID: 18369280     DOI: 10.1088/0031-9155/53/8/006

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  The accuracy of EGSnrc, Geant4 and PENELOPE Monte Carlo systems for the simulation of electron scatter in external beam radiotherapy.

Authors:  Bruce A Faddegon; Iwan Kawrakow; Yuri Kubyshin; Joseph Perl; Josep Sempau; Laszlo Urban
Journal:  Phys Med Biol       Date:  2009-09-24       Impact factor: 3.609

Review 2.  Present state and issues in IORT Physics.

Authors:  Frank W Hensley
Journal:  Radiat Oncol       Date:  2017-01-27       Impact factor: 3.481

3.  Dose distribution changes with shielding disc misalignments and wrong orientations in breast IOERT: a Monte Carlo - GEANT4 and experimental study.

Authors:  Giorgio Russo; Carlo Casarino; Gaetano Arnetta; Giuliana Candiano; Alessandro Stefano; Filippo Alongi; Giovanni Borasi; Cristina Messa; Maria C Gilardi
Journal:  J Appl Clin Med Phys       Date:  2012-09-06       Impact factor: 2.102

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.