Literature DB >> 18367808

Differences in myoelectric manifestations of fatigue in sprinters and long distance runners.

A Rainoldi1, M Gazzoni, G Melchiorri.   

Abstract

The aim of this study was to determine whether the rate of change of surface EMG variables during a constant force isometric fatiguing contraction (80% MVC, 30 s of duration) of vastus medialis obliquus (VMO) and vastus lateralis (VL) muscles is able to distinguish between nine sprinters and nine long distance runners. Signals were recorded with linear arrays of eight electrodes. Muscle fiber conduction velocity (CV), mean frequency (MNF) of EMG signal power spectrum and average rectified value (ARV) of the EMG signal were calculated both from the whole signal (global approach) and from motor unit action potentials (MUAP distribution approach) extracted from the signal. Results showed significant differences only in the MUAP distribution approach. For this approach, the rates of change of conduction velocity (CV) (both absolute and normalized with respect to the initial value) were found to be always greater in the sprinter (VMO: -0.012 +/- 0.011 m s(-2) and -0.25 +/- 0.21%/s; VL: -0.014 +/- 0.009 m s(-2) and -0.27 +/- 0.17%/s) than in the long distance runner group (VMO: -0.004 +/- 0.006 m s(-2) and -0.08 +/- 0.14%/s; VL: 0.003 +/- 0.012 m s(-2) and 0.08 +/- 0.26%/s) (VL: p = 0.016, VMO: p = 0.034). No differences were observed in the CV initial values and in rates of change of MNF, while MNF initial values recorded from the VMO were found to be greater (119.6 +/- 25.1 Hz) in the sprinter group than in the long distance runner group (99.2 +/- 12.1 Hz, p = 0.016). A correlation was found between initial values and rates of change of CV in the VMO (r = 0.61, p < 0.01, N = 18, Spearman correlation coefficient). The consistency of these findings with the expected fiber type composition between sprinters and long distance runners and the identification of a set of candidated variables for the assessment of muscle adaptation during training and/or rehabilitation programs represent the main results of the study.

Entities:  

Mesh:

Year:  2008        PMID: 18367808     DOI: 10.1088/0967-3334/29/3/004

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  5 in total

Review 1.  Fundamental Concepts of Bipolar and High-Density Surface EMG Understanding and Teaching for Clinical, Occupational, and Sport Applications: Origin, Detection, and Main Errors.

Authors:  Isabella Campanini; Andrea Merlo; Catherine Disselhorst-Klug; Luca Mesin; Silvia Muceli; Roberto Merletti
Journal:  Sensors (Basel)       Date:  2022-05-30       Impact factor: 3.847

2.  Quantification of high and low sEMG spectral components during sustained isometric contraction.

Authors:  Álvaro Costa-García; Eduardo Iáñez; Moeka Yokoyama; Sayako Ueda; Shotaro Okajima; Shingo Shimoda
Journal:  Physiol Rep       Date:  2022-05

3.  Field Programmable Gate Array-Embedded Platform for Dynamic Muscle Fiber Conduction Velocity Monitoring.

Authors:  Daniela De Venuto; Giovanni Mezzina
Journal:  Sensors (Basel)       Date:  2019-10-22       Impact factor: 3.576

4.  Myoelectrical manifestation of fatigue less prominent in patients with cancer related fatigue.

Authors:  Katarzyna Kisiel-Sajewicz; Vlodek Siemionow; Dilara Seyidova-Khoshknabi; Mellar P Davis; Alexandria Wyant; Vinoth K Ranganathan; Declan Walsh; Jin H Yan; Juliet Hou; Guang H Yue
Journal:  PLoS One       Date:  2013-12-31       Impact factor: 3.240

5.  Effects of Power and Ballistic Training on Table Tennis Players' Electromyography Changes.

Authors:  Amir Hossein Haghighi; Ali Zaferanieh; Seyed Alireza Hosseini-Kakhak; Ali Maleki; Fabio Esposito; Emiliano Cè; Carlos Castellar; Víctor Toro-Román; Francisco Pradas
Journal:  Int J Environ Res Public Health       Date:  2021-07-21       Impact factor: 3.390

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.