Literature DB >> 18367807

Development of a protocol to measure volatile organic compounds in human breath: a comparison of rebreathing and on-line single exhalations using proton transfer reaction mass spectrometry.

M E O'Hara1, S O'Hehir, S Green, C A Mayhew.   

Abstract

Analysis of volatile organic compounds (VOCs) on human breath has great potential as a non-invasive diagnostic technique. It is, therefore, surprising that no single, standard procedure has evolved for breath sampling. Here we present a novel repeated-cycle isothermal rebreathing method, where one cycle comprises five rebreaths, which could be adopted for breath analysis of VOCs. For demonstration purposes, we present measurements of three common breath VOCs: isoprene, acetone and methanol. Their concentrations measured in breath are shown to increase with number of rebreaths until a plateau value is reached by at least 20 rebreaths. The average ratio of plateau concentration to single mixed expired breath concentration was found to be 1.92 +/- 0.57 for isoprene, 1.25 +/- 0.13 for acetone and 1.12 +/- 0.12 for methanol (mean +/- standard deviation). Measurements from on-line single exhalations are presented which demonstrate a positive slope in the time-dependent expirograms of isoprene and acetone. The slope of the isoprene expirogram is persistently linear and the end-expired concentration of isoprene is highly variable in the same subject depending on the duration of exhalation. End-expired values of acetone are not as sensitive to the length of exhalation, and are the same to within measurement uncertainty for any duration of exhalation for any subject. It is concluded that uncontrolled single on-line exhalations are not suitable for the reliable measurement of isoprene in the breath and that rebreathing can be the basis of an easily tolerated protocol for the reliable collection of breath samples.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18367807     DOI: 10.1088/0967-3334/29/3/003

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  13 in total

1.  A mathematical model for breath gas analysis of volatile organic compounds with special emphasis on acetone.

Authors:  Julian King; Karl Unterkofler; Gerald Teschl; Susanne Teschl; Helin Koc; Hartmann Hinterhuber; Anton Amann
Journal:  J Math Biol       Date:  2011-01-14       Impact factor: 2.259

2.  Feasibility of skin acetone analysis in patients with cardiovascular diseases.

Authors:  Tetsuro Yokokawa; Takamasa Sato; Satoshi Suzuki; Masayoshi Oikawa; Akiomi Yoshihisa; Atsushi Kobayashi; Takayoshi Yamaki; Hiroyuki Kunii; Kazuhiko Nakazato; Takafumi Ishida; Yasuchika Takeishi
Journal:  Fukushima J Med Sci       Date:  2018-07-14

3.  2-Aminoacetophenone as a potential breath biomarker for Pseudomonas aeruginosa in the cystic fibrosis lung.

Authors:  Amy J Scott-Thomas; Mona Syhre; Philip K Pattemore; Michael Epton; Richard Laing; John Pearson; Stephen T Chambers
Journal:  BMC Pulm Med       Date:  2010-11-07       Impact factor: 3.317

4.  Noninvasive detection of lung cancer using exhaled breath.

Authors:  Xiao-An Fu; Mingxiao Li; Ralph J Knipp; Michael H Nantz; Michael Bousamra
Journal:  Cancer Med       Date:  2013-11-20       Impact factor: 4.452

5.  Breath analysis in disease diagnosis: methodological considerations and applications.

Authors:  Célia Lourenço; Claire Turner
Journal:  Metabolites       Date:  2014-06-20

6.  Limonene in exhaled breath is elevated in hepatic encephalopathy.

Authors:  M E O'Hara; R Fernández Del Río; A Holt; P Pemberton; T Shah; T Whitehouse; C A Mayhew
Journal:  J Breath Res       Date:  2016-11-21       Impact factor: 3.262

7.  Elimination characteristics of post-operative isoflurane levels in alveolar exhaled breath via PTR-MS analysis.

Authors:  R Fernández Del Río; M E O'Hara; P Pemberton; T Whitehouse; C A Mayhew
Journal:  J Breath Res       Date:  2016-10-12       Impact factor: 3.262

8.  Resolution enhancement of field asymmetric waveform ion mobility spectrometry (FAIMS) by ion focusing.

Authors:  Fei Tang; Chulong Xu; Xiaohao Wang
Journal:  Chem Cent J       Date:  2013-07-12       Impact factor: 4.215

9.  Volatile Biomarkers in Breath Associated With Liver Cirrhosis - Comparisons of Pre- and Post-liver Transplant Breath Samples.

Authors:  R Fernández Del Río; M E O'Hara; A Holt; P Pemberton; T Shah; T Whitehouse; C A Mayhew
Journal:  EBioMedicine       Date:  2015-07-26       Impact factor: 8.143

Review 10.  Exhaled breath analysis: a review of 'breath-taking' methods for off-line analysis.

Authors:  Oluwasola Lawal; Waqar M Ahmed; Tamara M E Nijsen; Royston Goodacre; Stephen J Fowler
Journal:  Metabolomics       Date:  2017-08-19       Impact factor: 4.290

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.