Image-guided radiosurgery for spinal tumors: methods, accuracy and patient intrafraction motion.

Nzhde Agazaryan1, Steve E Tenn, Antonio A F Desalles, Michael T Selch.   

Abstract

Image-guided frameless extracranial radiosurgery has become an established treatment option; however, without a frame to restrict patient movements, intrafraction field mispositioning becomes more probable. The primary aim of this study is to determine the intrafraction motion of spinal radiosurgery patients. This aim was approached in two steps. First, a phantom study demonstrated that the system can detect movements accurately within 0.1 mm and rotational changes within 0.2 degrees. Second, patient positioning and monitoring were carried out for a group of 15 patients with 20 treatment sites. For the patient pool in the study, vertebral anatomy movement was observed to vary as much as 3 mm between sequential measurements and could occur in as little as 5 min. These results suggest a need for intrafraction patient monitoring and correctional shifts, even for patients whose overall treatment times are expected to be relatively short. Small relative rotations with standard deviations of less than 1.5 degrees were observed. The small relative rotational movements observed do not, alone, justify patient monitoring using the image-guidance system during the treatments of generally small radiosurgical targets.

Entities:  

Mesh:

Year:  2008        PMID: 18367799     DOI: 10.1088/0031-9155/53/6/015

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  12 in total

1.  Is helical tomotherapy accurate and safe enough for spine stereotactic body radiotherapy?

Authors:  Yoonsun Chung; Hong In Yoon; Joo Ho Kim; Ki Chang Nam; Woong Sub Koom
Journal:  J Cancer Res Clin Oncol       Date:  2012-10-02       Impact factor: 4.553

2.  Prospective evaluation of target and spinal cord motion and dosimetric changes with respiration in spinal stereotactic body radiation therapy utilizing 4-D CT.

Authors:  Xin Wang; Amol J Ghia; Zhongxiang Zhao; Jinzhong Yang; Dershan Luo; Tina M Briere; Ramiro Pino; Jing Li; Mary F McAleer; David C Weksberg; Eric L Chang; Paul D Brown; James N Yang
Journal:  J Radiosurg SBRT       Date:  2016

3.  Image-guided linear accelerator-based spinal radiosurgery for hemangioblastoma.

Authors:  Michael T Selch; Steve Tenn; Nzhde Agazaryan; Steve P Lee; Alessandra Gorgulho; Antonio A F De Salles
Journal:  Surg Neurol Int       Date:  2012-07-14

4.  A level-wise spine registration framework to account for large pose changes.

Authors:  Yunliang Cai; Shaoju Wu; Xiaoyao Fan; Jonathan Olson; Linton Evans; Scott Lollis; Sohail K Mirza; Keith D Paulsen; Songbai Ji
Journal:  Int J Comput Assist Radiol Surg       Date:  2021-05-10       Impact factor: 3.421

5.  Comparison of measurement methods with a mixed effects procedure accounting for replicated evaluations (COM3PARE): method comparison algorithm implementation for head and neck IGRT positional verification.

Authors:  Anuradha Roy; Clifton D Fuller; David I Rosenthal; Charles R Thomas
Journal:  BMC Med Imaging       Date:  2015-08-28       Impact factor: 1.930

6.  Quantitative evaluation of patient setup uncertainty of stereotactic radiotherapy with the frameless 6D ExacTrac system using statistical modeling.

Authors:  Vance Keeling; Sabbir Hossain; Hosang Jin; Ozer Algan; Salahuddin Ahmad; Imad Ali
Journal:  J Appl Clin Med Phys       Date:  2016-05-08       Impact factor: 2.102

7.  A novel compound 6D-offset simulating phantom and quality assurance program for stereotactic image-guided radiation therapy system.

Authors:  Dennis Yuen Kan Ngar; Michael Lok-Man Cheung; Michael Koon-Ming Kam; Wai-Sang Poon; Anthony Tak-Cheung Chan
Journal:  J Appl Clin Med Phys       Date:  2014-11-04       Impact factor: 2.102

8.  Advances in fiducial-free image-guidance for spinal radiosurgery with CyberKnife--a phantom study.

Authors:  Christoph Fürweger; Christian Drexler; Markus Kufeld; Alexander Muacevic; Berndt Wowra
Journal:  J Appl Clin Med Phys       Date:  2010-12-22       Impact factor: 2.102

9.  Evaluation of Elements Spine SRS Plan Quality for SRS and SBRT Treatment of Spine Metastases.

Authors:  Michael Trager; Angelia Landers; Yan Yu; Wenyin Shi; Haisong Liu
Journal:  Front Oncol       Date:  2020-04-03       Impact factor: 6.244

10.  CyberKnife robotic spinal radiosurgery in prone position: dosimetric advantage due to posterior radiation access?

Authors:  Christoph Fürweger; Christian Drexler; Alexander Muacevic; Berndt Wowra; Erik C de Klerck; Mischa S Hoogeman
Journal:  J Appl Clin Med Phys       Date:  2014-07-08       Impact factor: 2.102

View more