Literature DB >> 18366082

3D finite element model of aqueous outflow to predict the effect of femtosecond laser created partial thickness drainage channels.

Dongyul Chai1, Gautam Chaudhary, Eric Mikula, Hui Sun, Tibor Juhasz.   

Abstract

BACKGROUND AND OBJECTIVES: Partial thickness drainage channels can be created with femtosecond lasers in the translucent sclera for the potential treatment of glaucoma. We present a 3D finite element model (FEM) that can predict the effect of these channels on aqueous humor (AH) outflow and intraocular pressure (IOP). STUDY DESIGN/
MATERIALS AND METHODS: A 3D model was developed based on a 2D model for the intact eye using COMSOL (Comsol, Inc., MA) finite element software. Different values of permeability were entered into the 3D model for the AH pathway and for the partial thickness channel. To obtain experimental data for model validation, one partial thickness channel was created in each of three enucleated rabbit eyes with a femtosecond laser tuned to 1.7 microm wavelength. Aqueous outflow rates were measured with the perfusion method before and after the laser treatments at different levels of IOP and then compared to IOP values predicted by the model.
RESULTS: The experiments indicated that the rate of the AH outflow was increased in each of three eyes after the laser treatment. Assuming a constant rate of AH production the 3D model predicted IOP reductions ranging from 67.2% to 80.6% as the effect of the laser created channels. These predictions were in reasonable agreement with experimentally adjusted IOP values during the perfusion measurements.
CONCLUSIONS: The developed 3D FEM has the potential to predict IOP reduction caused by partial thickness drainage channels created with the femtosecond laser in the sclera. Such a model may also be used to determine optimal channel dimensions for a specified increase in outflow facility and reduction in IOP. (c) 2008 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2008        PMID: 18366082     DOI: 10.1002/lsm.20608

Source DB:  PubMed          Journal:  Lasers Surg Med        ISSN: 0196-8092            Impact factor:   4.025


  4 in total

1.  External sclerostomy with the femtosecond laser versus a surgical knife in rabbits.

Authors:  Yao Shi; Xiao-Bo Yang; Neng-Li Dai; Hua Long; Pei-Xiang Lu; Ling Jin; Fa-Gang Jiang
Journal:  Int J Ophthalmol       Date:  2012-06-18       Impact factor: 1.779

2.  Evaluation of human sclera after femtosecond laser ablation using two photon and confocal microscopy.

Authors:  Hui Sun; Ronald Kurtz; Tibor Juhasz
Journal:  J Biomed Opt       Date:  2012-08       Impact factor: 3.170

3.  In vivo femtosecond laser subsurface scleral treatment in rabbit eyes.

Authors:  Dongyul Chai; Gautam Chaudhary; Eric Mikula; Hui Sun; Ron Kurtz; Tibor Juhasz
Journal:  Lasers Surg Med       Date:  2010-09       Impact factor: 4.025

4.  Intraocular Pressure Reduction by Femtosecond Laser Created Trabecular Channels in Perfused Human Anterior Segments.

Authors:  Eric Mikula; Guy Holland; Samantha Bradford; Reza Khazaeinezhad; Hadi Srass; Carlos Suarez; James V Jester; Tibor Juhasz
Journal:  Transl Vis Sci Technol       Date:  2021-08-02       Impact factor: 3.048

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.