Literature DB >> 18365824

Iodinated contrast media: effect of osmolarity and injection temperature on erythrocyte morphology in vitro.

J M Kerl1, S A Nguyen, J Lazarchick, J W Powell, M W Oswald, F Alvi, P Costello, T J Vogl, U J Schoepf.   

Abstract

BACKGROUND: Some side effects of intravenously injected iodinated contrast media are thought to be linked to the biological properties of the various agents and their effect on blood components.
PURPOSE: To assess the effect of osmolarity and injection temperature of iodinated contrast media on erythrocyte (RBC) morphology in vitro.
MATERIAL AND METHODS: Blood from 20 volunteers was incubated with three different contrast media (320 mg I/ml iso-osmolar iodixanol, 300 mg I/ml low-osmolar iopromide, 300 mg I/ml low-osmolar iopamidol) injected at 37 degrees C, 43 degrees C, and 48 degrees C, and in two different volumes corresponding to the estimated concentration at the site of venous injection and after systemic distribution. After 10 min incubation, aliquots were removed for complete blood count analysis and blood smears. Two hematologists blindedly and independently reviewed all smears, and determined the grade of morphological RBC changes compared to a blank sample.
RESULTS: There was excellent (kappa = 0.98) inter-reader correlation for grading RBC changes. At systemic concentration at 37 degrees C, the grade of RBC changes was significantly (P<0.05) less in blood samples exposed to iso-osmolar iodixanol (mean 0.21) as compared to low-osmolar iopromide (mean 0.26) and low-osmolar iopamidol (mean 0.58). These differences became more significant at higher volumes, corresponding to concentrations at the site of injection and higher injection temperatures.
CONCLUSION: In vitro, RBC morphology is less affected by iso-osmolar as compared to low-osmolar contrast media. These differences become more significant at higher injection temperatures that are proposed to improve flow dynamics for high-speed injection.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18365824     DOI: 10.1080/02841850801885978

Source DB:  PubMed          Journal:  Acta Radiol        ISSN: 0284-1851            Impact factor:   1.990


  5 in total

1.  Contrast Media Adverse Drug Reactions in Highly Polluted Environment.

Authors:  Natalia Sauer; Wojciech Szlasa; Laura Jonderko; Krystyna Głowacka; Katarzyna Karłowicz-Bodalska; Anna Wiela-Hojeńska
Journal:  Int J Environ Res Public Health       Date:  2022-06-09       Impact factor: 4.614

2.  Acute pulmonary edema induced by non-ionic low-osmolar radiographic contrast media.

Authors:  Laurence Pincet; Gabriele Lecca
Journal:  Open Access Emerg Med       Date:  2018-06-14

3.  Effect of radiographic contrast media on the spectrin/band3-network of the membrane skeleton of erythrocytes.

Authors:  Ralf-Peter Franke; Tim Scharnweber; Rosemarie Fuhrmann; Folker Wenzel; Anne Krüger; Christof Mrowietz; Friedrich Jung
Journal:  PLoS One       Date:  2014-02-24       Impact factor: 3.240

Review 4.  Effects of radiographic contrast media on the micromorphology of the junctional complex of erythrocytes visualized by immunocytology.

Authors:  Ralf-Peter Franke; Anne Krüger; Tim Scharnweber; Folker Wenzel; Friedrich Jung
Journal:  Int J Mol Sci       Date:  2014-09-12       Impact factor: 5.923

Review 5.  Renal Safety of Iodinated Contrast Media Depending on Their Osmolarity - Current Outlooks.

Authors:  Bartosz Mruk
Journal:  Pol J Radiol       Date:  2016-04-11
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.