Literature DB >> 18360853

Stent fracture, an incidental finding or a significant marker of clinical in-stent restenosis?

Fareed Shaikh1, Rajesh Maddikunta, Mohamed Djelmami-Hani, Joaquin Solis, Suhail Allaqaband, Tanvir Bajwa.   

Abstract

BACKGROUND: The predictors and clinical significance for stent fracture (SF) in drug-eluting stents (DES) remain unknown. We identified procedural factors leading to SF and its clinical consequences in DES.
METHODS: Percutaneous coronary interventions were performed on 3,920 patients with DES over 12 months. In-stent restenosis (ISR) of DES was observed in 188 cases with 121 cases (64.4%) receiving a sirolimus-eluting stent (SES) and 67 (35.6%) a paclitaxol-eluting stent (PES).
RESULTS: SF was identified in 35 (18.6%) of the 188 cases. The 35 cases were then compared with 153 cases of ISR without angiographic evidence of SF. SF was identified in 29 (23.9%) SES compared with 6 (9.0%) in PES (P < 0.05). With univariate analysis, additional factors associated with SF included longer mean stented segment length, male gender, overlapping stents, vessel segment angulation >75 degrees , and more stents (all P < 0.05). With multivariate adjustment, three factors, i.e., stenting on a bend >75 degrees (OR = 13.8, 95%CI 3.7 to 51; P < 0.001), SES (OR = 4.1, 95%CI 1.3 to 13.4; P < 0.018) and overlapping stented segments (OR = 3.9, 95%CI 1.1 to 14.1; P < 0.041) were statistically significant independent predictors of SF while larger stent diameter was protective (OR = 0.14, 95%CI 0.04 to 0.70; P < 0.017).
CONCLUSION: SF proved to be associated with angiographically-documented clinical ISR. Although the exact mechanism is unknown, factors that appear to play a negative role in SF include vessel tortuosity, use of SES and overlapping stents. Larger stent diameter was protective. Further studies are needed to better define the factors important in the mechanism of SF. Copyright 2008 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18360853     DOI: 10.1002/ccd.21371

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  16 in total

1.  Long-term angiographic outcomes of post-sirolimus-eluting stent restenosis in Japanese patients.

Authors:  Nobuyuki Miyai; Noriyuki Kinoshita; Keisuke Oota; Takeshi Yamada; Reo Nakamura; Hidekazu Irie; Tetsuo Hashimoto; Shyunichi Tamaki; Hiroaki Matsubara
Journal:  Heart Vessels       Date:  2010-10-27       Impact factor: 2.037

2.  Prevalence and prognosis of coronary stent gap detected by multi-detector CT: a follow-up study.

Authors:  Xinghua Zhang; Li Yang; Haiyue Ju; Fan Zhang; Jian Wu; Bin He; Yundai Chen
Journal:  Eur Radiol       Date:  2012-04-27       Impact factor: 5.315

Review 3.  Assessment of drug-eluting stents and bioresorbable stents by grayscale IVUS and IVUS-based imaging modalities.

Authors:  Salvatore Brugaletta; Jose Ribamar Costa; Hector M Garcia-Garcia
Journal:  Int J Cardiovasc Imaging       Date:  2011-01-30       Impact factor: 2.357

4.  Extensive late-acquired incomplete stent apposition after sirolimus-eluting stent implantation.

Authors:  Hyun-Chul Choi; Seung-Ho Hur; Chang-Wook Nam; Yun-Kyeong Cho; Hyungseop Kim; Nam-Hee Park; Yoon-Nyun Kim; Kwon-Bae Kim
Journal:  Korean Circ J       Date:  2010-01-27       Impact factor: 3.243

5.  Fracture of zotarolimus-eluting stent after implantation.

Authors:  Meng-Chieh Wu; Chen-Chuan Cheng; Tsuei-Yuan Huang
Journal:  Tex Heart Inst J       Date:  2009

6.  Clinical characteristics of coronary drug-eluting stent fracture: insights from a two-center des registry.

Authors:  Kyung Woo Park; Jin Joo Park; In-Ho Chae; Jae-Bin Seo; Han-Mo Yang; Hae-Young Lee; Hyun-Jae Kang; Young-Seok Cho; Tae-Jin Yeon; Woo-Young Chung; Bon-Kwon Koo; Dong-Ju Choi; Byung-Hee Oh; Young-Bae Park; Hyo-Soo Kim
Journal:  J Korean Med Sci       Date:  2010-12-22       Impact factor: 2.153

7.  A case of a zotarolimus-eluting stent fracture in the left anterior descending artery in a patient undergoing hemodialysis.

Authors:  In Hye Cha; Seong Hwan Kim; Sang Yup Lim; Jeong Chun Ahn; Woo Hyuk Song
Journal:  Chonnam Med J       Date:  2011-04-26

8.  Pathologic Etiologies of Late and Very Late Stent Thrombosis following First-Generation Drug-Eluting Stent Placement.

Authors:  Fumiyuki Otsuka; Masataka Nakano; Elena Ladich; Frank D Kolodgie; Renu Virmani
Journal:  Thrombosis       Date:  2012-11-21

9.  Stent fracture: how frequently is it recognized?

Authors:  Mohammed Khalil Mohsen; Awad Alqahtani; Jassim Al Suwaidi
Journal:  Heart Views       Date:  2013-04

Review 10.  Coronary stent fracture: a recently appreciated phenomenon with clinical relevance.

Authors:  Madjid Chinikar; Parham Sadeghipour
Journal:  Curr Cardiol Rev       Date:  2014-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.