Literature DB >> 18360533

Ultrasensitive absorption spectroscopy with a high-finesse optical cavity and off-axis alignment.

J B Paul, L Lapson, J G Anderson.   

Abstract

A simple and easy to use method that allows high-finesse optical cavities to be used as absorption cells for spectroscopic purposes is presented. This method introduces a single-mode continuous-wave laser into the cavity by use of an off-axis cavity alignment geometry to eliminate systematically the resonances commonly associated with optical cavities, while preserving the absorption signal amplifying properties of such cavities. This considerably reduces the complexity of the apparatus compared with other high-resolution cavity-based absorption methods. Application of this technique in conjunction with either cavity ringdown spectroscopy or integrated cavity output spectroscopy produced absorption sensitivities of 1.5 x 10(-9) cm(-1) Hz(-1/2) and 1.8 x 10(-10) cm(-1) Hz(-1/2), respectively.

Year:  2001        PMID: 18360533     DOI: 10.1364/ao.40.004904

Source DB:  PubMed          Journal:  Appl Opt        ISSN: 1559-128X            Impact factor:   1.980


  10 in total

1.  Optical re-injection in cavity-enhanced absorption spectroscopy.

Authors:  J Brian Leen; Anthony O'Keefe
Journal:  Rev Sci Instrum       Date:  2014-09       Impact factor: 1.523

2.  SAM-CAAM: A Concept for Acquiring Systematic Aircraft Measurements to Characterize Aerosol Air Masses.

Authors:  Ralph A Kahn; Tim A Berkoff; Charles Brock; Gao Chen; Richard A Ferrare; Steven Ghan; Thomas F Hansico; Dean A Hegg; J Vanderlei Martins; Cameron S McNaughton; Daniel M Murphy; John A Ogren; Joyce E Penner; Peter Pilewskie; John H Seinfeld; Douglas R Worsnop
Journal:  Bull Am Meteorol Soc       Date:  2017-10-30       Impact factor: 8.766

3.  Laser spectroscopy for atmospheric and environmental sensing.

Authors:  Marc N Fiddler; Israel Begashaw; Matthew A Mickens; Michael S Collingwood; Zerihun Assefa; Solomon Bililign
Journal:  Sensors (Basel)       Date:  2009-12-22       Impact factor: 3.576

4.  Stratospheric controlled perturbation experiment: a small-scale experiment to improve understanding of the risks of solar geoengineering.

Authors:  John A Dykema; David W Keith; James G Anderson; Debra Weisenstein
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2014-12-28       Impact factor: 4.226

5.  No influence of CO2 on stable isotope analyses of soil waters with off-axis integrated cavity output spectroscopy (OA-ICOS).

Authors:  Matthias Sprenger; Doerthe Tetzlaff; Chris Soulsby
Journal:  Rapid Commun Mass Spectrom       Date:  2017-03-15       Impact factor: 2.419

6.  Sensitive Spectroscopy of Acetone Using a Widely Tunable External-Cavity Quantum Cascade Laser.

Authors:  Faisal Nadeem; Julien Mandon; Amir Khodabakhsh; Simona M Cristescu; Frans J M Harren
Journal:  Sensors (Basel)       Date:  2018-06-27       Impact factor: 3.576

7.  RES-Q-Trace: A Mobile CEAS-Based Demonstrator for Multi-Component Trace Gas Detection in the MIR.

Authors:  Norbert Lang; Uwe Macherius; Henrik Zimmermann; Sven Glitsch; Mathias Wiese; Jürgen Röpcke; Jean-Pierre H van Helden
Journal:  Sensors (Basel)       Date:  2018-06-27       Impact factor: 3.576

8.  Estimating Regional Methane Emission Factors from Energy and Agricultural Sector Sources Using a Portable Measurement System: Case Study of the Denver-Julesburg Basin.

Authors:  Stuart N Riddick; Fancy Cheptonui; Kexin Yuan; Mercy Mbua; Rachel Day; Timothy L Vaughn; Aidan Duggan; Kristine E Bennett; Daniel J Zimmerle
Journal:  Sensors (Basel)       Date:  2022-09-29       Impact factor: 3.847

Review 9.  Aspects of the application of cavity enhanced spectroscopy to nitrogen oxides detection.

Authors:  Jacek Wojtas; Janusz Mikolajczyk; Zbigniew Bielecki
Journal:  Sensors (Basel)       Date:  2013-06-10       Impact factor: 3.576

10.  Off-Axis Cavity-Enhanced Absorption Spectroscopy of 14NH3 in Air Using a Gain-Switched Frequency Comb at 1.514 μm.

Authors:  Satheesh Chandran; Albert A Ruth; Eamonn P Martin; Justin K Alexander; Frank H Peters; Prince M Anandarajah
Journal:  Sensors (Basel)       Date:  2019-11-28       Impact factor: 3.576