Literature DB >> 18359819

Influence of suture material on the biomechanical behavior of suture-tendon specimens: a controlled study in bovine rotator cuff.

Leslie J Bisson1, Leslie M Manohar, Ryan D Wilkins, Jennifer Gurske-Deperio, Mark T Ehrensberger.   

Abstract

BACKGROUND: Despite technical advances in rotator cuff surgery, recurrent or persistent defects in the repaired tendon continue to occur. Improved strength of sutures and suture anchors has resulted in the most common site of failure being the suture-tendon interface. HYPOTHESIS: The type of suture material used has a significant effect on the biomechanics of the suture-tendon interface. STUDY
DESIGN: Controlled laboratory study.
METHODS: Thirty-two bovine infraspinatus specimens were randomly assigned to simple suture fixation using No. 2 Fiberwire, Ultrabraid, Orthocord, or Ethibond. Each specimen was subjected to cyclic testing from 5 to 30 N for 30 cycles, followed by load-to-failure testing.
RESULTS: Cyclic testing revealed significantly greater elongation with Ultrabraid, whereas peak-to-peak displacements were lowest for Fiberwire and greatest for Orthocord. Load-to-failure testing revealed no significant differences between any suture material for ultimate tensile load. Fiberwire and Orthocord repairs had the highest stiffness. The most common failure mode during load-to-failure testing was suture breakage in Ethibond specimens and suture cutting through the tendon in the polyblend suture specimens.
CONCLUSION: The type of suture material has a significant effect on the biomechanical behavior of the suture-tendon interface. CLINICAL RELEVANCE: The type of suture may influence early gap formation and ultimate healing of rotator cuff repairs.

Entities:  

Mesh:

Year:  2008        PMID: 18359819     DOI: 10.1177/0363546508314793

Source DB:  PubMed          Journal:  Am J Sports Med        ISSN: 0363-5465            Impact factor:   6.202


  18 in total

1.  [Biomechanical investigation on refixation of tuberosities on shoulder prostheses. Does refixation with different suture materials offer enough stability?].

Authors:  J Fleischer; A Schleyer; R Nassutt; H Grundei; U Grittner; S J Hopp
Journal:  Unfallchirurg       Date:  2010-08       Impact factor: 1.000

2.  Tendon-grasping strength of various suture configurations for rotator cuff repair.

Authors:  Onur Hapa; F Alan Barber; Emin Sünbüloğlu; Yavuz Kocabey; Nazlı Sarkalkan; Gökhan Baysal
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-11-18       Impact factor: 4.342

3.  Biomechanical evaluation of different suture materials for arthroscopic transtibial pull-out repair of posterior meniscus root tears.

Authors:  Matthias J Feucht; Eduardo Grande; Johannes Brunhuber; Nikolaus Rosenstiel; Rainer Burgkart; Andreas B Imhoff; Sepp Braun
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-09-03       Impact factor: 4.342

4.  Beyond the square knot: a novel knotting technique for surgical use.

Authors:  Chunfeng Zhao; Chung-Chen Hsu; Tamami Moriya; Andrew R Thoreson; Steven S Cha; Steven L Moran; Kai-Nan An; Peter C Amadio
Journal:  J Bone Joint Surg Am       Date:  2013-06-05       Impact factor: 5.284

5.  Effects of using a surgical clamp to hold tension while tying knots with commonly used orthopedic sutures.

Authors:  Leslie J Bisson; Andrew D Sobel; David Godfrey
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-09-16       Impact factor: 4.342

6.  Suture Anchor Versus Transosseous Tunnel Repair for Inferior Pole Patellar Fractures Treated With Partial Patellectomy and Tendon Advancement: A Biomechanical Study.

Authors:  Ryan O'Donnell; Nicholas J Lemme; Stephen Marcaccio; Devin F Walsh; Kalpit N Shah; Brett D Owens; Steven F DeFroda
Journal:  Orthop J Sports Med       Date:  2021-08-16

7.  From Bench to Bedside: Semper Gumby-Like Living Tissue, Let's Stay Flexible.

Authors:  Benjamin K Potter
Journal:  Clin Orthop Relat Res       Date:  2021-06-01       Impact factor: 4.755

8.  Tendon-bone contact pressure and biomechanical evaluation of a modified suture-bridge technique for rotator cuff repair.

Authors:  Mike H Baums; Michael Geyer; Meike Büschken; Gottfried H Buchhorn; Gunter Spahn; Hans-Michael Klinger
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-10-14       Impact factor: 4.342

9.  Tendon Collagen Crosslinking Offers Potential to Improve Suture Pullout in Rotator Cuff Repair: An Ex Vivo Sheep Study.

Authors:  Roland S Camenzind; Karl Wieser; Gion Fessel; Dominik C Meyer; Jess G Snedeker
Journal:  Clin Orthop Relat Res       Date:  2016-04-18       Impact factor: 4.176

10.  High-Strength Suture Tapes Are Biomechanically Stronger Than High-Strength Sutures Used in Rotator Cuff Repair.

Authors:  Paul Borbas; Lukas Fischer; Lukas Ernstbrunner; Armando Hoch; Elias Bachmann; Samy Bouaicha; Karl Wieser
Journal:  Arthrosc Sports Med Rehabil       Date:  2021-06-15
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.