Transient and distortion product evoked oto-acoustic emissions in normal hearing patients with and without tinnitus.

Ronaldo C Granjeiro1, Helga M Kehrle, Roberta L Bezerra, Vanessa F Almeida, André L L Sampaio, Carlos A Oliveira.   

Abstract

OBJECTIVE: To test the hypothesis that tinnitus begins with outer hair cell dysfunction by recording transient (TEOAE) and distortion product evoked (DPOAE) oto-acoustic emissions in patients with normal hearing with (study group, SG) and without tinnitus (control group, CG). STUDY
DESIGN: Case control study. SUBJECTS AND METHODS: SG had 32 patients with pure tone thresholds below 25 dB in the 500 to 8000 Hz interval. CG had 37 age- and gender-matched patients with similar thresholds. All patients had normal tympanograms and stapedial reflexes. TEOAE were recorded with wide band click in continuous mode at 80-dB peak SPL. DPOAE were recorded with f1/f2 = 1.22 and intensities of 65 dB (f1) and 55 dB (f2) SPL.
RESULTS: DPOAE were abnormal in 68.4% of SG and in 50% of CG (P = 0.036). TEOAE were abnormal in 70.2% of SG and in 16.10% of CG (P = 0.0001).
CONCLUSION: SG had significantly higher prevalence of abnormal TEOAE and DPOAE than CG.

Entities:  

Mesh:

Year:  2008        PMID: 18359362     DOI: 10.1016/j.otohns.2007.11.012

Source DB:  PubMed          Journal:  Otolaryngol Head Neck Surg        ISSN: 0194-5998            Impact factor:   3.497


  10 in total

1.  The Association Between Cochlear and Retrocochlear Disorders with Tinnitus with Normal Hearing Thresholds.

Authors:  Emmy Pramesthi Dyah Soelistijani; Nyilo Purnami; M S Wiyadi
Journal:  Indian J Otolaryngol Head Neck Surg       Date:  2018-04-10

2.  Comparison of the Transient Evoked Otoacoustic Emissions (TEOAEs) and Distortion Products Otoacoustic Emissions (DPOAEs) in Normal Hearing Subjects With and Without Tinnitus.

Authors:  Maryam Emadi; Mohammad Rezaei; Sirvan Najafi; Ali Faramarzi; Farhad Farahani
Journal:  Indian J Otolaryngol Head Neck Surg       Date:  2015-01-20

3.  The relationship between tinnitus pitch and hearing sensitivity.

Authors:  Giriraj Singh Shekhawat; Grant D Searchfield; Cathy M Stinear
Journal:  Eur Arch Otorhinolaryngol       Date:  2013-02-13       Impact factor: 2.503

4.  Objective assessment of subjective tinnitus through contralateral suppression of otoacoustic emissions by white noise: effects of frequency, gender, tinnitus bilaterality and age.

Authors:  M Riga; A Komis; P Maragoudakis; G Korres; E Ferekidis; V Danielides
Journal:  Acta Otorhinolaryngol Ital       Date:  2018-04       Impact factor: 2.124

Review 5.  The study of otoacoustic emissions and the suppression of otoacoustic emissions in subjects with tinnitus and normal hearing: an insight to tinnitus etiology.

Authors:  Lucieny Serra; Gabriela Novanta; Andre Lopes Sampaio; Carlos Augusto Oliveira; Ronaldo Granjeiro; Silvia Cristina Braga
Journal:  Int Arch Otorhinolaryngol       Date:  2014-06-18

6.  Evaluation of distortion and transient evoked otoacoustic emission in tinnitus patients with normal hearing.

Authors:  Helnaz Mokrian; Abdolreza Shaibanizadeh; Saeid Farahani; Shohreh Jalaie; Parvane Mahdi; Amin Amali; Homa Arian Nahad
Journal:  Iran J Otorhinolaryngol       Date:  2014-01

7.  The relationship between ultra-high frequency thresholds and transient evoked otoacoustic emissions in adults with tinnitus.

Authors:  Shaghayegh Omidvar; Zahra Jafari; Saeid Mahmoudian; Mehdi Khabazkhoob; Mohsen Ahadi; Nasrin Yazdani
Journal:  Med J Islam Repub Iran       Date:  2016-11-26

8.  Effect of Age, Gender and Hearing Loss on the Degree of Discomfort Due to Tinnitus.

Authors:  Maryam Noroozian; Zahra Jafari; Elaheh Shahmiri; Shaghayegh Omidvar; Azadeh Zendehbad; Naser Amini; Mahsa Radmehr; Masoud Bagherian; Ali Yoonessi
Journal:  Basic Clin Neurosci       Date:  2017 Nov-Dec

9.  Audiological biomarkers of tinnitus in an older Portuguese population.

Authors:  Haúla F Haider; Diogo Ribeiro; Sara F Ribeiro; Nuno Trigueiros; Helena Caria; Luís Borrego; Iola Pinto; Ana L Papoila; Derek J Hoare; João Paço
Journal:  Front Aging Neurosci       Date:  2022-08-24       Impact factor: 5.702

10.  The relationship between distortion product otoacoustic emissions and extended high-frequency audiometry in tinnitus patients. Part 1: normally hearing patients with unilateral tinnitus.

Authors:  Anna Fabijańska; Jacek Smurzyński; Stavros Hatzopoulos; Krzysztof Kochanek; Grażyna Bartnik; Danuta Raj-Koziak; Manuela Mazzoli; Piotr H Skarżyński; Wieslaw W Jędrzejczak; Agata Szkiełkowska; Henryk Skarżyński
Journal:  Med Sci Monit       Date:  2012-12