| Literature DB >> 18353736 |
Lie Li1, Deepthi Pabbisetty, Paulo Carvalho, Mitchell A Avery, John S Williamson, Bonnie A Avery.
Abstract
A rapid and sensitive ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed and validated to quantify artemisinin in rat serum. The lower limit of quantification (LLOQ) was 4 ng/mL. The calibration curve was linear from 4 ng/mL to 10,000 ng/mL (R=0.998). The assay was based on the selected reaction monitoring (SRM) transitions at m/z 305.4-151.10 for artemisinin and m/z 335.2-163.10 for arteether (internal standard). The artemisinin and internal standard can be separated from endogenous interferences in rat serum. Inter- and intra-day assay variation was less than 15%. The extraction recoveries ranged from 80.0 to 107.3% at the three concentrations (5000, 2000, and 200 ng/mL). This method was successfully applied to pharmacokinetic studies of artemisinin after intravenous and oral administration to rats.Entities:
Mesh:
Substances:
Year: 2008 PMID: 18353736 DOI: 10.1016/j.jchromb.2008.01.057
Source DB: PubMed Journal: J Chromatogr B Analyt Technol Biomed Life Sci ISSN: 1570-0232 Impact factor: 3.205