OBJECTIVES: Report the results of a phase II multicenter, prospective trial comparing endovascular treatment of descending thoracic aneurysm (TEVAR) with the TAG device to surgical controls after 5 years of follow-up.
METHODS: The Gore TAG trial compared the TAG endograft patients (n = 140) with standard open surgical controls (n = 94) with enrollment from September of 1999 to May of 2001. An additional 51 patients were enrolled in 2003 after revision of the endograft. Follow-up consisted of patient visits, computed tomography (CT) scans and x-rays at 1, 6, and 12 months and yearly. Significant sac size change was defined as >or=5 mm increase or decrease from the 1 month baseline measurement. Migration was defined as >or=10 mm cranial or caudal movement of the device inside the aorta. Significance was determined as P <or= .05.
RESULTS: At 5 years, aneurysm-related mortality was lower for TAG patients at 2.8% compared with open controls at 11.7% (P = .008). No differences in all-cause mortality were noted, with 68% of TAG patients and 67% of open controls surviving to 5 years (P = .43). Major adverse events at 5 years were significantly reduced in the TAG group; 57.9% vs 78.7% (P = .001). Endoleaks in the TAG group decreased from 8.1% at 1 month to 4.3% at 5 years. Five TAG patients have undergone major aneurysm-related re-interventions at 5 years (3.6%), including one arch aneurysm repair for type 1 endoleak and migration, one open conversion and five endovascular procedures for endoleaks in three patients. There were fewer secondary procedures not directly related to aneurysm repair in the TAG vs the open repair group at 5 years, 15.0% vs 31.9%, (P = .01). For TAG patients, sac size at 60 months decreased in 50% and increased in 19% compared with the 1-month baseline. Comparison with the modified low-porosity device at 24 months showed sac increase in 12.9% of original vs 2.9% in modified grafts (P = .11). At 5 years, there have been no ruptures, one migration, no collapse, and 20 instances of fracture in 19 patients, all before the revision of the TAG graft.
CONCLUSIONS: In anatomically suitable patients, TAG treatment of thoracic aneurysms is superior to surgical repair at 5 years. Although sac enlargement is concerning, early modified device results indicate this issue may be resolved.

Entities:  

Mesh:

Year:  2008        PMID: 18353605     DOI: 10.1016/j.jvs.2007.12.006

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  58 in total

Review 1.  [Thoracic aortic aneurysm].

Authors:  D Kotelis; P Geisbüsch; M Hakimi; D Böckler
Journal:  Chirurg       Date:  2012-04       Impact factor: 0.955

Review 2.  TEVAR: Endovascular Repair of the Thoracic Aorta.

Authors:  David A Nation; Grace J Wang
Journal:  Semin Intervent Radiol       Date:  2015-09       Impact factor: 1.513

3.  High mortality rates after both open surgical and endovascular thoracic aortic interventions in patients with end-stage renal disease.

Authors:  Nathan L Liang; Theodore H Yuo; Georges E Al-Khoury; Eric S Hager; Michel S Makaroun; Michael J Singh
Journal:  J Vasc Surg       Date:  2017-04-08       Impact factor: 4.268

4.  Practice patterns for thoracic aneurysms in the stent graft era: health care system implications.

Authors:  Karen L Walker; Jonathan J Shuster; Tomas D Martin; Philip J Hess; Charles T Klodell; Robert J Feezor; Adam W Beck; Thomas M Beaver
Journal:  Ann Thorac Surg       Date:  2010-12       Impact factor: 4.330

Review 5.  Complications of endovascular aneurysm repair of the thoracic and abdominal aorta: evaluation and management.

Authors:  Dania Daye; T Gregory Walker
Journal:  Cardiovasc Diagn Ther       Date:  2018-04

6.  Endovascular repair of the thoracic aorta.

Authors:  Grace J Wang; Ronald M Fairman
Journal:  Semin Intervent Radiol       Date:  2009-03       Impact factor: 1.513

7.  Initial Experience of Modified Four-Branched Graft Technique and Antegrade TEVAR in Acute Type A Aortic Dissection.

Authors:  Hung-Tao Chou; Jen-Ping Lo; Chai-Hock Chua; Ming-Jen Lu; Chia-Hsun Lin
Journal:  Ann Thorac Cardiovasc Surg       Date:  2015-05-25       Impact factor: 1.520

8.  Hybrid Treatment with Complete Transposition of Supra-Aortic Trunks versus Conventional Surgery for the Treatment of Aortic Arch Aneurysm.

Authors:  Leonardo de Oliveira Souza; Rodrigo de Castro Bernardes; Túlio Pinho Navarro; Ricardo Jayme Procópio; Fernando Antônio Roquete Reis; Luiz Claudio Moreira Lima; Ernesto Lentz da Silveira
Journal:  Braz J Cardiovasc Surg       Date:  2017 Sep-Oct

9.  A review of endovascular treatment of thoracic aorta disease.

Authors:  Gjs Tan; Plz Khoo; Kmj Chan
Journal:  Ann R Coll Surg Engl       Date:  2018-10-05       Impact factor: 1.891

10.  Preoperative prediction of mortality within 1 year after elective thoracic endovascular aortic aneurysm repair.

Authors:  Salvatore T Scali; Catherine K Chang; Robert J Feezor; Philip J Hess; Thomas M Beaver; Tomas D Martin; Thomas S Huber; Adam W Beck
Journal:  J Vasc Surg       Date:  2012-07-25       Impact factor: 4.268

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.