Literature DB >> 18353501

Ultrasonically nebulised electrolysed oxidising water: a promising new infection control programme for impressions, metals and gypsum casts used in dental hospitals.

G Wu1, X Yu, Z Gu.   

Abstract

Controlling the transmission of infectious diseases by impressions, metals and dental casts in dental hospitals remains a challenge. Current disinfection methods have various drawbacks. This study introduced and provided a preliminary evaluation of the feasibility of using ultrasonically nebulised, electrolysed oxidising water (UNEOW) as a new infection control programme. UNEOW was produced from freshly generated electrolysed oxidising water (EOW). Samples of impressions, titanium and gypsum were subjected to the following treatments: (1) immersion in 1% sodium hypochlorite for 10min; (2) immersion in EOW for 10min; (3) exposure to UNEOW for 15, 30 and 45min; (4) no disinfection (control). Bactericidal efficacy was examined using Staphylococcus aureus and Bacillus subtilis var. niger spores as indicators. Dimensional accuracy, surface quality, and effect of corrosion were also evaluated for the different samples. Results showed that except for B. subtilis var. niger spores on gypsum casts, the bacterial reduction log(10) values after 30-45min treatment with UNEOW were all above 4. The impression dimensional changes showed no difference between control and UNEOW groups, but both were significantly lower than the EOW and sodium hypochlorite groups (P<0.05). The same was true for the surface quality of impressions and gypsum casts. No assessable corrosion was found on the titanium surface after a 45min treatment with UNEOW. The findings indicated that use of UNEOW is a feasible and promising approach for controlling the transmission of infectious diseases by impressions, gypsum casts and denture metals in dental facilities.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18353501     DOI: 10.1016/j.jhin.2008.01.024

Source DB:  PubMed          Journal:  J Hosp Infect        ISSN: 0195-6701            Impact factor:   3.926


  5 in total

1.  Preliminary SEM Observations on the Surface of Elastomeric Impression Materials after Immersion or Ozone Disinfection.

Authors:  Nikolas Poulis; Anthony Prombonas; Stavros Yannikakis; Thanasis Karampotsos; Martha-Spyridoula Katsarou; Nikolaos Drakoulis
Journal:  J Clin Diagn Res       Date:  2016-12-01

2.  Comparative evaluation of the effect of electrolyzed oxidizing water on surface detail reproduction, dimensional stability and Surface texture of poly vinyl siloxane impressions.

Authors:  A S Mahalakshmi; Vidhya Jeyapalan; Vallabh Mahadevan; Chitra Shankar Krishnan; N S Azhagarasan; Hariharan Ramakrishnan
Journal:  J Indian Prosthodont Soc       Date:  2019 Jan-Mar

3.  Suitability of electrolyzed oxidizing water for the disinfection of hard surfaces and equipment in radiology.

Authors:  Robert Pintaric; Joze Matela; Stefan Pintaric
Journal:  J Environ Health Sci Eng       Date:  2015-01-28

4.  In vitro evaluation of dimensional stability of alginate impressions after disinfection by spray and immersion methods.

Authors:  Fahimeh Hamedi Rad; Tahereh Ghaffari; Sayed Hamed Safavi
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2010-12-21

5.  Effect of mixing techniques on bacterial attachment and disinfection time of polyether impression material.

Authors:  Umut Guler; Yasemin Budak; Emrah Ruh; Yesim Ocal; Senay Canay; Yakut Akyon
Journal:  Eur J Dent       Date:  2013-09
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.