Literature DB >> 18350646

Glare and halo with refractive correction.

Richard J Allen1, George M Saleh, Andre S Litwin, Andrea Sciscio, Adrian B Beckingsale, Frederick W Fitzke.   

Abstract

BACKGROUND: The aim of this investigation was to compare glare and halo with various methods of refractive correction.
METHODS: Ninety-eight eyes of healthy pre-presbyopes were analysed for the presence of glare and halo using computer-generated stimuli. Subjects were divided into three groups: emmetropes without correction, single vision plastic lens spectacle wearers (with clean and dirty lenses) or single-vision soft contact lens wearers.
RESULTS: No significant difference in glare was found among groups. Significant differences were noted in halos between emmetropes and both contact lens (p<0.001) and uncleaned spectacle groups (p<0.05) but not with cleaned spectacles. The reduction in halo size after cleaning the lenses was significant (p<0.0187).
CONCLUSIONS: Contact lens and unclean spectacle wearers both have significantly larger halos than emmetropes and those wearing cleaned spectacle lenses. Unclean spectacles may affect the accuracy of results in psychophysical and clinical testing.

Mesh:

Year:  2008        PMID: 18350646     DOI: 10.1111/j.1444-0938.2007.00220.x

Source DB:  PubMed          Journal:  Clin Exp Optom        ISSN: 0816-4622            Impact factor:   2.742


  1 in total

1.  Minimum pupil in pupillary response to light and myopia affect disk halo size: a cross-sectional study.

Authors:  Feng Zhao; Tian Han; Xun Chen; Zhi Chen; Ke Zheng; Xiaoying Wang; Xingtao Zhou
Journal:  BMJ Open       Date:  2018-04-10       Impact factor: 2.692

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.