Literature DB >> 18345262

Evaluation of transcutaneous bilirubinometry in preterm infants of gestational age 32-34 weeks.

Lucia Stillova1, Katarina Matasova, Tatiana Mikitova, Juraj Stilla, Hana Kolarovszka, Mirko Zibolen.   

Abstract

AIMS: The aim of this prospective study was to evaluate the accuracy of transcutaneous bilirubinometry using the Minolta Air-Shields JM-103 device in preterm newborns of gestational age 32-34 weeks, and to identify the most appropriate measurement site.
METHODS: Transcutaneous bilirubin (TcB) measurements were performed over forehead, sternum and abdomen, if total serum bilirubin (TSB) had to be determined on clinical indication in neonates of selected gestational age. TSB levels were measured in a clinical laboratory using direct spectrophotometry. In order to assess transcutaneous bilirubinometry accuracy, differences between TSB and TcB, their CI 95%, and correlation coefficients (r) between TcB and TSB were evaluated.
RESULTS: The study group consisted of 44 infants, including 6 very low birth weight (VLBW) neonates. The correlations between transcutaneous and laboratory values were found to be significant and close. Minimal differences were observed when measured over sternum. The measurements over forehead had a tendency to underestimate TSB levels.
CONCLUSIONS: Noninvasive measurement by Minolta JM-103 demonstrated significant accuracy. The authors recommend measurements over sternum or abdomen in premature infants born within 32-34 gestational weeks as a reliable and accurate neonatal hyperbilirubinemia screening test. Transcutaneous bilirubinometry has the potential to reduce the number of blood samplings, thus reducing neonatal pain and discomfort, parental distress and medical care cost.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18345262     DOI: 10.5507/bp.2007.045

Source DB:  PubMed          Journal:  Biomed Pap Med Fac Univ Palacky Olomouc Czech Repub        ISSN: 1213-8118            Impact factor:   1.245


  2 in total

1.  Accuracy of transcutaneous bilirubin measurement in preterm low-birth-weight neonates.

Authors:  Deepak Chawla; Suksham Jain; Gurjit Kaur; Vikas Sinhmar; Vishal Guglani
Journal:  Eur J Pediatr       Date:  2013-08-17       Impact factor: 3.183

2.  The forehead is a better site than the sternum to check transcutaneous bilirubin during phototherapy in sick infants.

Authors:  Jaesung Jeon; Gina Lim; Ki Won Oh; Na Mi Lee; Hye Won Park; Mi Lim Chung
Journal:  BMC Pediatr       Date:  2020-12-05       Impact factor: 2.125

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.