Negative tracheal pressure during neonatal endotracheal suction.

Nicholas J Kiraly1, David G Tingay, John F Mills, Colin J Morley, Beverley Copnell.   

Abstract

Endotracheal tube (ETT) suction is the most frequently performed invasive procedure in ventilated newborn infants and is associated with adverse effects related to negative tracheal pressure. We aimed to measure suction catheter gas flow and intratracheal pressure during ETT suction of a test lung and develop a mathematical model to predict tracheal pressure from catheter and ETT dimensions and applied pressure. Tracheal pressure and catheter flow were recorded during suction of ETT sizes 2.5-4.0 mm connected to a test lung with catheters 5-8 French Gauge and applied pressures of 80-200 mm Hg. The fraction of applied pressure transmitted to the trachea was calculated for each combination, and data fitted to three nonlinear models for analysis. Tracheal pressure was directly proportional to applied pressure (r = 0.82-0.99), and catheter flow fitted a turbulent flow model (R = 0.85-0.96). With each ETT, increasing catheter size resulted in greater catheter flow (p < 0.0001) and thus lower intratracheal pressure (p < 0.0001). The fraction of applied pressure transmitted to the trachea was accurately modeled using ETT and catheter dimensions (R = 0.98-0.99). Negative tracheal pressure during in vitro ETT suction is directly proportional to applied pressure. This relationship is determined by ETT and catheter dimensions.

Entities:  

Mesh:

Year:  2008        PMID: 18344905     DOI: 10.1203/PDR.0b013e31817289dc

Source DB:  PubMed          Journal:  Pediatr Res        ISSN: 0031-3998            Impact factor:   3.756


  4 in total

1.  The effect of endotracheal suction on regional tidal ventilation and end-expiratory lung volume.

Authors:  D G Tingay; B Copnell; C A Grant; P A Dargaville; K R Dunster; A Schibler
Journal:  Intensive Care Med       Date:  2010-03-16       Impact factor: 17.440

Review 2.  Frequency of endotracheal suctioning for the prevention of respiratory morbidity in ventilated newborns.

Authors:  Matteo Bruschettini; Simona Zappettini; Lorenzo Moja; Maria Grazia Calevo
Journal:  Cochrane Database Syst Rev       Date:  2016-03-07

Review 3.  Endotracheal suctioning in intubated newborns: an integrative literature review.

Authors:  Roberta Lins Gonçalves; Lucila Midori Tsuzuki; Marcos Giovanni Santos Carvalho
Journal:  Rev Bras Ter Intensiva       Date:  2015 Jul-Sep

4.  Effect of closed endotracheal suction in high-frequency ventilated premature infants measured with electrical impedance tomography.

Authors:  Mariëtte B van Veenendaal; Martijn Miedema; Frans H C de Jongh; Johanna H van der Lee; Inez Frerichs; Anton H van Kaam
Journal:  Intensive Care Med       Date:  2009-09-23       Impact factor: 17.440

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.