The effect of relative needle diameter in puncture and sham injection animal models of degeneration.

Dawn M Elliott1, Chandra S Yerramalli, Jesse C Beckstein, John I Boxberger, Wade Johannessen, Edward J Vresilovic.   

Abstract

STUDY
DESIGN: Biomechanical study and literature review.
OBJECTIVES: To quantify the acute effect of needle diameter on the in vitro mechanical properties of cadaver lumbar discs in the rat and sheep. To review published in vivo animal studies and evaluate disc changes with respect to the relative needle size. SUMMARY OF BACKGROUND DATA: There are many cases where a disc needle puncture or injection is applied to animal models: puncture injuries to induce degeneration, chemonucleolysis to induce degeneration, and delivery of disc therapies. It is not clear what role the size of the needle may have in the outcome.
METHODS: Mechanics were measured after sham phosphate buffered saline injection with a 27 G or 33 G needle in the rat and with a 27 G needle in the sheep. A literature review was performed to evaluate studies in which animal discs were treated with a needle puncture or a sham injection. For each study, the ratio of the needle diameter to disc height (needle:height) was calculated.
RESULTS: When the rat was injected with a 27 G needle (52% of disc height), the compression, tension, and neutral zone stiffnesses were 20% to 60% below preinjected values and the neutral zone length was 130% higher; when injected with a 33 G needle (26% of disc height), the only affected property was the neutral zone length, which was only 20% greater. When the sheep was injected with a 27 G needle (10% of disc height), none of the axial properties were different from intact, the torsion stiffness was not different, and the torque range was 15% smaller. Twenty-three in vivo studies in the rat, rabbit, dog, or sheep were reviewed. The disc changes depended on the ratio of needle diameter to disc height as follows: significant changes were not observed for needle:height less than 40%, although between 25% and 40% results were variable and some minor nonsignificant effects were observed, disc changes were universal for needle:height over 40%.
CONCLUSION: A needle puncture may directly alter mechanical properties via nucleus pulposus depressurization and/or anulus fibrosus damage, depending on the relative needle size. As more basic science research is aimed at treating disc degeneration via injection of therapeutic factors, these findings provide guidance in design of animal studies. Such studies should consider the relative needle size and include sham control groups to account for the potential effects of the needle injection.

Entities:  

Mesh:

Year:  2008        PMID: 18344851     DOI: 10.1097/BRS.0b013e318166e0a2

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  98 in total

Review 1.  Diagnostic discography: what is the clinical utility?

Authors:  David A Provenzano
Journal:  Curr Pain Headache Rep       Date:  2012-02

2.  In vitro and in silico investigations of disc nucleus replacement.

Authors:  Sandra Reitmaier; Aboulfazl Shirazi-Adl; Maxim Bashkuev; Hans-Joachim Wilke; Antonio Gloria; Hendrik Schmidt
Journal:  J R Soc Interface       Date:  2012-02-15       Impact factor: 4.118

3.  Penetrating annulus fibrosus injuries affect dynamic compressive behaviors of the intervertebral disc via altered fluid flow: an analytical interpretation.

Authors:  Arthur J Michalek; James C Iatridis
Journal:  J Biomech Eng       Date:  2011-08       Impact factor: 2.097

4.  Design Requirements for Annulus Fibrosus Repair: Review of Forces, Displacements, and Material Properties of the Intervertebral Disk and a Summary of Candidate Hydrogels for Repair.

Authors:  Rose G Long; Olivia M Torre; Warren W Hom; Dylan J Assael; James C Iatridis
Journal:  J Biomech Eng       Date:  2016-02       Impact factor: 2.097

5.  The effects of needle puncture injury on microscale shear strain in the intervertebral disc annulus fibrosus.

Authors:  Arthur J Michalek; Mark R Buckley; Lawrence J Bonassar; Itai Cohen; James C Iatridis
Journal:  Spine J       Date:  2010-10-23       Impact factor: 4.166

6.  CT-guided injection technique into intervertebral discs in the ovine lumbar spine.

Authors:  Jean Francois Nisolle; Fabienne Neveu; Fanny Hontoir; Peter Clegg; Nathalie Kirschvink; Jean-Michel Vandeweerd
Journal:  Eur Spine J       Date:  2013-08-11       Impact factor: 3.134

7.  Surgical anatomy, transperitoneal approach, and early postoperative complications of a ventral lumbar spine surgical model in Lewis rats.

Authors:  Sheela R Damle; Agata Krzyzanowska; Robert J Frawley; Matthew E Cunningham
Journal:  Comp Med       Date:  2013-10       Impact factor: 0.982

8.  Injection of human umbilical tissue-derived cells into the nucleus pulposus alters the course of intervertebral disc degeneration in vivo.

Authors:  Steven K Leckie; Gwendolyn A Sowa; Bernard P Bechara; Robert A Hartman; Joao Paulo Coelho; William T Witt; Qing D Dong; Brent W Bowman; Kevin M Bell; Nam V Vo; Brian C Kramer; James D Kang
Journal:  Spine J       Date:  2013-02-04       Impact factor: 4.166

Review 9.  Mechanical design criteria for intervertebral disc tissue engineering.

Authors:  Nandan L Nerurkar; Dawn M Elliott; Robert L Mauck
Journal:  J Biomech       Date:  2010-01-18       Impact factor: 2.712

10.  A large animal model that recapitulates the spectrum of human intervertebral disc degeneration.

Authors:  S E Gullbrand; N R Malhotra; T P Schaer; Z Zawacki; J T Martin; J R Bendigo; A H Milby; G R Dodge; E J Vresilovic; D M Elliott; R L Mauck; L J Smith
Journal:  Osteoarthritis Cartilage       Date:  2016-08-26       Impact factor: 6.576