Literature DB >> 18343015

Use of an ultrasound blood-mimicking fluid for Doppler investigations of turbulence in vitro.

Meghan L Thorne1, Tamie L Poepping, Richard N Rankin, David A Steinman, David W Holdsworth.   

Abstract

Turbulence is an important factor in the assessment of stenotic disease and a possible causative mechanism for thromboembolism. Previous Doppler studies of turbulence have typically used whole-blood preparations or suspensions of erythrocytes. Recently, a water-glycerol based blood-mimicking fluid (BMF) has been developed for use in Doppler ultrasound studies. This fluid has desirable ultrasound properties but it has not previously been described during in vitro investigations of turbulence intensity. We report on investigations of grid-generated and constrained-jet turbulence in an in vitro test system. The BMF was found to generate significant levels of turbulence during steady flow at physiological flow rates, producing turbulent patterns in the distal region that were consistent with previous studies. Turbulence intensity increased significantly with flow rate (p < 0.005) for both the constrained jet and the constrained grid. Based on our observations, we conclude that a water-glycerol based BMF provides a suitable working fluid during in vitro investigations of turbulence using Doppler ultrasound.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18343015     DOI: 10.1016/j.ultrasmedbio.2007.12.014

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  6 in total

1.  Evaluation of distal turbulence intensity for the detection of both plaque ulceration and stenosis grade in the carotid bifurcation using clinical Doppler ultrasound.

Authors:  Emily Y Wong; Hristo N Nikolov; Richard N Rankin; David W Holdsworth; Tamie L Poepping
Journal:  Eur Radiol       Date:  2012-12-18       Impact factor: 5.315

2.  Clinical Doppler ultrasound for the assessment of plaque ulceration in the stenosed carotid bifurcation by detection of distal turbulence intensity: a matched model study.

Authors:  Emily Y Wong; Hristo N Nikolov; Meghan L Thorne; Tamie L Poepping; Richard N Rankin; David W Holdsworth
Journal:  Eur Radiol       Date:  2009-06-23       Impact factor: 5.315

Review 3.  A Review of Suspension-Scattered Particles Used in Blood-Mimicking Fluid for Doppler Ultrasound Imaging.

Authors:  Ammar A Oglat; Nursakinah Suardi; M Z Matjafri; Mohammad A Oqlat; Mostafa A Abdelrahman; Ahmad A Oqlat
Journal:  J Med Ultrasound       Date:  2018-05-07

4.  Compatibility and Validation of a Recent Developed Artificial Blood through the Vascular Phantom Using Doppler Ultrasound Color- and Motion-mode Techniques.

Authors:  Marwan Alshipli; Mohannad Adel Sayah; Ammar A Oglat
Journal:  J Med Ultrasound       Date:  2020-04-23

Review 5.  Chemical Items Used for Preparing Tissue-Mimicking Material of Wall-Less Flow Phantom for Doppler Ultrasound Imaging.

Authors:  Ammar A Oglat; M Z Matjafri; Nursakinah Suardi; Mohammad A Oqlat; Mostafa A Abdelrahman; Ahmad A Oqlat; Omar F Farhat; Batool N Alkhateb; Raed Abdalrheem; Muntaser S Ahmad; Mohammed Y M Abujazar
Journal:  J Med Ultrasound       Date:  2018-05-07

6.  A New Scatter Particle and Mixture Fluid for Preparing Blood Mimicking Fluid for Wall-Less Flow Phantom.

Authors:  Ammar A Oglat; M Z Matjafri; Nursakinah Suardi; Mostafa A Abdelrahman; Mohammad A Oqlat; Ahmad A Oqlat
Journal:  J Med Ultrasound       Date:  2018-09-14
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.