Literature DB >> 18341957

Similarity of the swine vasculature to the human carotid bifurcation: analysis of arterial diameters.

Doron Bushi1, Yaron Assaf, Ygael Grad, Boaz Nishri, Ofer Yodfat, David Tanne.   

Abstract

PURPOSE: We assessed the similarities of the iliac bifurcation in two breeds of swine to the known human carotid bifurcation, in order to assess its applicability as a preclinical model of the human carotid bifurcation.
MATERIALS AND METHODS: Mixed-Landrace crossbreed (domestic; n = 66) and Yucatan miniswine (Yucatan; n = 13) were studied. The diameters of the iliac bifurcation arteries were measured from angiographic pictures, the relations between the arterial diameters and the animal's weight assessed, and diametrical ratios calculated. Findings were compared with the known human carotid bifurcation.
RESULTS: The external iliac diameter (approximately 6-7mm) in the lower weight swine was similar to the known human common carotid artery. The best similarity was found between the diametrical ratios of the human internal to common carotid artery (mean 0.63) to the swine profunda to external iliac (means 0.68 and 0.65 for the domestic and Yucatan, respectively). The arterial diameters of the domestic swine were highly correlated with their weight that increased considerably with time, while in the Yucatan group, arterial diameters did not change with increasing weight and the average weight increase rate was low. Thus, the estimated arterial diameter increase rate over time was high in the domestic while minor in the Yucatan group.
CONCLUSIONS: Similarities were found between the swine iliac bifurcation arteries to the human carotid bifurcation in terms of diameters, diametrical ratios and angle. The swine iliac bifurcation may be used for preclinical endovascular research of devices intended to the human carotid bifurcation, with miniswine strains a preferable model for long-term studies.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18341957     DOI: 10.1016/j.jvir.2007.09.022

Source DB:  PubMed          Journal:  J Vasc Interv Radiol        ISSN: 1051-0443            Impact factor:   3.464


  3 in total

1.  Measurement of peripheral arterial vasculature in domestic Yorkshire swine by using quantitative vascular angiography.

Authors:  Vanessa C Lopes-Berkas; Michael A Jorgenson
Journal:  J Am Assoc Lab Anim Sci       Date:  2011-09       Impact factor: 1.232

2.  Functional lengths of the lower limb arterial tree measured by CT angiography centreline analysis: implications for catheter lengths in peripheral angioplasty.

Authors:  Asif Naleem; Ali Zaman; Kai Low; Matthew D Tam
Journal:  Surg Radiol Anat       Date:  2013-08-17       Impact factor: 1.246

3.  Measurement of the Luminal Diameter of Peripheral Arterial Vasculature in Yorkshire×Landrace Swine by Using Ultrasonography and Angiography.

Authors:  Keping Zuo; Li Buay Koh; Christopher J Charles; Evelyn Kf Yim; Jialing Lim; Renee R Li; Hwa Liang Leo; Fangsen Cui; Pei Ho
Journal:  J Am Assoc Lab Anim Sci       Date:  2020-06-12       Impact factor: 1.232

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.