Literature DB >> 18340627

Comparison between pulsed-wave Doppler- and tissue Doppler-derived Tei indices in fetuses with and without congenital heart disease.

G Acharya1, M Pavlovic, L Ewing, D Nollmann, J Leshko, J C Huhta.   

Abstract

OBJECTIVES: The aim of this study was to compare the right (RV) and left (LV) ventricular Tei indices obtained by pulsed-wave Doppler (PD) and tissue Doppler (TD) methods in fetuses with structurally normal and abnormal hearts.
METHODS: This was a retrospective cross-sectional study of 147 fetuses that had a fetal echocardiogram and Tei index measured during a 2-year period. The RV and LV Tei indices were measured using both PD and TD methods. The difference between the two methods of Tei index measurement was tested using paired sample t-test, Pearson correlation coefficient was used to examine their relationship, and the agreement between the methods was tested using Bland-Altman analysis.
RESULTS: A total of 87 fetuses had normal hearts and 60 had a congenital heart defect. Both PD and TD Tei indices were measured successfully from at least one ventricle in 123 cases and from both ventricles in 110 cases. The mean TD Tei index was significantly higher than the mean PD Tei index for both ventricles (P < 0.0001). There was a weak but statistically significant correlation between the PD and TD Tei indices of the right ventricle (r = 0.20, P = 0.029), whereas the PD and TD Tei indices of the left ventricle did not correlate significantly (r = 0.04, P = 0.684). When pairs of Tei indices measured by two different methods (123 pairs for the right ventricle and 111 for the left ventricle) were tested with Bland-Altman analysis, the bias and precision were 0.147 and 0.254, respectively, for the right ventricle, and 0.299 and 0.276, respectively, for the left ventricle.
CONCLUSIONS: Correlation between Tei indices measured by PD and TD methods is weak and the agreement between individual measurements is poor. Therefore, they should not be used interchangeably in the assessment of fetal cardiac function. Copyright (c) 2008 ISUOG. Published by John Wiley & Sons, Ltd.

Entities:  

Mesh:

Year:  2008        PMID: 18340627     DOI: 10.1002/uog.5292

Source DB:  PubMed          Journal:  Ultrasound Obstet Gynecol        ISSN: 0960-7692            Impact factor:   7.299


  7 in total

Review 1.  Echocardiographic evaluation of right heart function and pulmonary vascular bed.

Authors:  Federico Cacciapuoti
Journal:  Int J Cardiovasc Imaging       Date:  2009-07-26       Impact factor: 2.357

2.  Fetal cardiac function: Feasibility in obtaining the right modified myocardial performance index in a single Doppler waveform.

Authors:  Neama Meriki; Alec W Welsh
Journal:  Australas J Ultrasound Med       Date:  2017-02-01

3.  Abnormal left ventricular relaxation and symptoms of heart failure.

Authors:  Maryam Nabati; Safora Salehi; Babak Bagheri; Mahmoud Nouraei
Journal:  J Echocardiogr       Date:  2016-04-04

Review 4.  Ultrasound assessment of fetal cardiac function.

Authors:  Fàtima Crispi; Brenda Valenzuela-Alcaraz; Monica Cruz-Lemini; Eduard Gratacós
Journal:  Australas J Ultrasound Med       Date:  2015-12-31

5.  A non-invasive multimodal foetal ECG-Doppler dataset for antenatal cardiology research.

Authors:  Eleonora Sulas; Monica Urru; Roberto Tumbarello; Luigi Raffo; Reza Sameni; Danilo Pani
Journal:  Sci Data       Date:  2021-01-26       Impact factor: 6.444

6.  Reference values for fetal tissue velocity imaging and a new approach to evaluate fetal myocardial function.

Authors:  Nina Ne Elmstedt; Jonas Jj Johnson; Britta Bl Lind; Kjerstin Kfw Ferm-Widlund; Lotta Lh Herling; Magnus Mw Westgren; Lars-Åke Lab Brodin
Journal:  Cardiovasc Ultrasound       Date:  2013-08-16       Impact factor: 2.062

7.  Neurological Outcomes after Human Umbilical Cord Patch for In Utero Spina Bifida Repair in a Sheep Model.

Authors:  Ramesha Papanna; Lovepreet K Mann; Saul Snowise; Yisel Morales; Sanjay P Prabhu; Scheffer C G Tseng; Raymond Grill; Stephen Fletcher; Kenneth J Moise
Journal:  AJP Rep       Date:  2016-07
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.