Literature DB >> 18340246

Optimization of low-contrast detectability in thin-collimated modern multidetector CT using an interactive sliding-thin-slab averaging algorithm.

Christian von Falck1, Alexander Hartung, Frank Berndzen, Benjamin King, Michael Galanski, Hoen-oh Shin.   

Abstract

OBJECTIVES: To analyze the effects of the sliding-thin-slab averaging algorithm on low-contrast performance in MDCT imaging and to find reasonable parameters for clinical routine work.
MATERIALS AND METHODS: A low-contrast phantom simulating hypodense lesions (20 HU object contrast) was scanned with a 16-slice spiral CT scanner using different mAs-settings of 25, 50, 100, and 195 mAs. Other scan parameters were as follows: tube voltage = 120 kVp, slice collimation = 0.625 mm, pitch = 1.375 (high speed), reconstruction interval = 0.5 mm. Images were reconstructed with soft, standard, and bone algorithms, resulting in a total of 12 datasets. A sliding-thin-slab averaging algorithm was applied to these primary datasets, systematically varying the slab thickness between 0.5 and 5.0 mm. The low-contrast performance of the resulting datasets was semi-automatically analyzed using a statistical reader-independent approach: A size-dependent analysis of the image noise within the phantom was used to empirically generate a contrast discrimination function (CDF). The ratio between the actual contrast and the minimum contrast necessary for the detection (as given by the CDF) was calculated for all lesions in each dataset and used to evaluate the low-contrast detectability of the different lesions at increasing slab thickness. The results were compared with the original datasets to calculate the improvement in low-contrast detectability.
RESULTS: Using the sliding-thin-slab algorithm, low-contrast performance was increased by a factor between 1.1 and 1.7 when compared with the primary dataset. The improvement of the visibility index at optimal slab thickness when compared with the original slice thickness (0.625 mm) was statistically significant (P < 0.05, Student t test) for the following datasets: 8 mm: all datasets; 6 mm: 25 mAs/soft, 195 mAs/bone, 25 mAs/bone; 5 mm: 25 mAs/soft, 25 mAs/bone. The ideal slab thickness over all datasets was 43% (+/-3%) of the diameter of the lesion to be detected.
CONCLUSIONS: The use of an interactive sliding-thin-slab averaging algorithm can be readily applied to optimize low-contrast detectability in thin-collimated CT datasets. As a general rule for daily routine, a slice thickness of approximately 2.5 to 3.0 mm can be regarded as a reasonable preset, resulting in an optimized detectability of lesions with a diameter of 5 mm and above.

Entities:  

Mesh:

Year:  2008        PMID: 18340246     DOI: 10.1097/RLI.0b013e3181614f2d

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  4 in total

1.  Emergency department CT screening of patients with nontraumatic neurological symptoms referred to the posterior fossa: comparison of thin versus thick slice images.

Authors:  Shervin Kamalian; Wendy L Atkinson; Lauren A Florin; Stuart R Pomerantz; Michael H Lev; Javier M Romero
Journal:  Emerg Radiol       Date:  2014-01-28

2.  Observer-independent nodule-detectability index for low-dose lung cancer screening CT: a pilot study.

Authors:  Masaki Ohkubo; Shinichi Wada; Satoshi Kanai; Kazuhiro Ishikawa; Janaka C Marasinghe; Toru Matsumoto
Journal:  Radiol Phys Technol       Date:  2013-06-09

Review 3.  CT radiation dose optimization and estimation: an update for radiologists.

Authors:  Hyun Woo Goo
Journal:  Korean J Radiol       Date:  2011-12-23       Impact factor: 3.500

4.  Influence of sinogram affirmed iterative reconstruction of CT data on image noise characteristics and low-contrast detectability: an objective approach.

Authors:  Christian von Falck; Vesela Bratanova; Thomas Rodt; Bernhard Meyer; Stephan Waldeck; Frank Wacker; Hoen-oh Shin
Journal:  PLoS One       Date:  2013-02-13       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.