Literature DB >> 18339396

Comparison of dual solvent-stir bars microextraction and U-shaped hollow fiber-liquid phase microextraction for the analysis of Sudan dyes in food samples by high-performance liquid chromatography-ultraviolet/mass spectrometry.

Chunhe Yu1, Qing Liu, Lidan Lan, Bin Hu.   

Abstract

Two sample preparation methods, dual solvent-stir bars microextraction (DSSBME) and U-shaped hollow fiber-liquid phase microextraction (U-shaped HF-LPME), are proposed and critically compared for high-performance liquid chromatography (HPLC)-ultraviolet (UV)/mass spectrometry (MS) analysis of Sudan dyes in this paper. In DSSBME, the organic solvent was confined to a pair of hollow fiber membrane fixed on a stir bar, which can stir by itself, while the hollow fiber in U-shaped HF-LPME was fixed by two microsyringes. The significant factors affecting the microextraction of Sudan dyes in both microextraction techniques have been examined and no obvious difference in the effect of extraction solvent, pH and salt concentration on the extraction efficiency of Sudan dyes was observed except extraction time and stirring speed. Both microextraction techniques were similar in terms of analytical performance from aqueous solutions (LODs ranged from 0.09 to 0.95 microgL(-1) by HPLC-UV and 2.5-6.2 microgL(-1) by HPLC-MS; the absolute LODs ranged from 0.9 to 11.25 pg by HPLC-UV and 5-21.2 pg by HPLC-MS), however, DSSBME was more stable (lower stirring speed required), less sample consuming and much shorter time required to reach extraction equilibrium; while U-shaped HF-LPME was easier to operate and no more special device required. The two microextraction techniques combined with HPLC-UV/MS were successfully applied to the analysis of real samples including strawberry sauce, capsicum oil, salted egg, and two kinds of chilli sauce. Although the LODs of HPLC-UV are lower than that of HPLC-MS by a factor of 10 in this work, the absolute LODs for both HPLC-UV and HPLC-MS are comparable. HPLC-UV cannot identify the suspicious peaks at the same retention time as that of Sudan II and III in salted egg, while HPLC-MS can give exact information of Sudan I-IV in real sample analysis and is more reliable. The sensitivity of HPLC-MS is enough for real sample analysis.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18339396     DOI: 10.1016/j.chroma.2008.02.065

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  2 in total

1.  Preparation of new hydrophobic deep eutectic solvents and their application in dispersive liquid-liquid microextraction of Sudan dyes from food samples.

Authors:  Dandan Ge; Zhizhuo Shan; Tongqing Pang; Xiaomin Lu; Baoling Wang
Journal:  Anal Bioanal Chem       Date:  2021-05-08       Impact factor: 4.142

2.  Solvent stir bar microextraction technique with three-hollow fiber configuration for trace determination of nitrite in river water samples.

Authors:  Hamid Badiee; Mohammad Ali Zanjanchi; Abbasali Zamani; Armin Fashi
Journal:  Environ Sci Pollut Res Int       Date:  2019-09-11       Impact factor: 4.223

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.