Literature DB >> 18339217

Heat transfer coefficient: Medivance Arctic Sun Temperature Management System vs. water immersion.

M J English1, T M Hemmerling.   

Abstract

BACKGROUND AND
OBJECTIVE: To improve heat transfer, the Medivance Arctic Sun Temperature Management System (Medivance, Inc., Louisville, CO, USA) features an adhesive, water-conditioned, highly conductive hydrogel pad for intimate skin contact. This study measured and compared the heat transfer coefficient (h), i.e. heat transfer efficiency, of this pad (hPAD), in a heated model and in nine volunteers' thighs; and of 10 degrees C water (hWATER) in 33 head-out immersions by 11 volunteers.
METHODS: Volunteer studies had ethical approval and written informed consent. Calibrated heat flux transducers measured heat flux (W m-2). Temperature gradient (DeltaT) was measured between skin and pad or water temperatures. Temperature gradient was changed through the pad's water temperature controller or by skin cooling on immersion.
RESULTS: The heat transfer coefficient is the slope of W m-2/DeltaT: its unit is W m-2 degrees C-1. Average with (95% CI) was: model, hPAD = 110.4 (107.8-113.1), R2 = 0.99, n = 45; volunteers, hPAD = 109.8 (95.5-124.1), R2 = 0.83, n = 51; and water immersion, hWATER = 107.1 (98.1-116), R2 = 0.86, n = 94.
CONCLUSION: The heat transfer coefficient for the pad was the same in the model and volunteers, and equivalent to hWATER. Therefore, for the same DeltaT and heat transfer area, the Arctic Sun's heat transfer rate would equal water immersion. This has important implications for body cooling/rewarming rates.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18339217     DOI: 10.1017/S0265021508003931

Source DB:  PubMed          Journal:  Eur J Anaesthesiol        ISSN: 0265-0215            Impact factor:   4.330


  4 in total

1.  Treatment of resistant fever: new method of local cerebral cooling.

Authors:  Susanne Mink; Urs Schwarz; Regina Mudra; Christoph Gugl; Jürg Fröhlich; Emanuela Keller
Journal:  Neurocrit Care       Date:  2011-08       Impact factor: 3.210

2.  Nonpharmacologic approach to minimizing shivering during surface cooling: a proof of principle study.

Authors:  Nirav G Shah; Mark J Cowan; Edward Pickering; Houtan Sareh; Majid Afshar; Dawn Fox; Jennifer Marron; Jennifer Davis; Keith Herold; Carl B Shanholtz; Jeffrey D Hasday
Journal:  J Crit Care       Date:  2012-07-02       Impact factor: 3.425

3.  The effects of physiological thermoregulation on the efficacy of surface cooling for therapeutic hypothermia.

Authors:  Mayank Kalra; Majid Bahrami; Carolyn J Sparrey
Journal:  Med Biol Eng Comput       Date:  2014-11-23       Impact factor: 2.602

4.  Bullous Lesions After Use of a Commercial Therapeutic Hypothermia Temperature Management System: A Possible Burn Injury?

Authors:  Henry E Wang; James M Wells; Dana V Rizk
Journal:  Ther Hypothermia Temp Manag       Date:  2013-09       Impact factor: 1.286

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.