Literature DB >> 18338002

Effect of multiple light paths on retinal vessel oximetry.

M H Smith1, K R Denninghoff, A Lompado, L W Hillman.   

Abstract

Techniques for noninvasively measuring the oxygen saturation of blood in retinal arteries and veins are reported in the literature, but none have been sufficiently accurate and reliable for clinical use. Addressing the need for increased accuracy, we present a series of oximetric equations that explicitly consider the effects of backscattering by red blood cells and lateral diffusion of light in the ocular fundus. The equations are derived for the specific geometry of a scanning-beam retinal vessel oximeter; however, the results should also be applicable to photographic oximeters. We present in vitro and in vivo data that suggest the validity of these equations.

Entities:  

Year:  2000        PMID: 18338002     DOI: 10.1364/ao.39.001183

Source DB:  PubMed          Journal:  Appl Opt        ISSN: 1559-128X            Impact factor:   1.980


  9 in total

1.  Retinal oximeter for the blue-green oximetry technique.

Authors:  Kurt R Denninghoff; Katarzyna B Sieluzycka; Jennifer K Hendryx; Tyson J Ririe; Lawrence Deluca; Russell A Chipman
Journal:  J Biomed Opt       Date:  2011-10       Impact factor: 3.170

Review 2.  Retinal oxygen: from animals to humans.

Authors:  Robert A Linsenmeier; Hao F Zhang
Journal:  Prog Retin Eye Res       Date:  2017-01-18       Impact factor: 21.198

3.  Monte Carlo Investigation of Optical Coherence Tomography Retinal Oximetry.

Authors:  Siyu Chen; Ji Yi; Wenzhong Liu; Vadim Backman; Hao F Zhang
Journal:  IEEE Trans Biomed Eng       Date:  2015-05-04       Impact factor: 4.538

4.  Hyperspectral Image Mapping Spectrometry for Retinal Oximetry Measurements in Four Diseased Eyes.

Authors:  Jason G Dwight; Christina Y Weng; Robert E Coffee; Michal E Pawlowski; Tomasz S Tkaczyk
Journal:  Int Ophthalmol Clin       Date:  2016

5.  Sub-millimeter resolution 3D optical imaging of living tissue using laminar optical tomography.

Authors:  Elizabeth M C Hillman; Sean A Burgess
Journal:  Laser Photon Rev       Date:  2009-02-01       Impact factor: 13.138

6.  A Dye-Free Analog to Retinal Angiography Using Hyperspectral Unmixing to Retrieve Oxyhemoglobin Abundance.

Authors:  Jason G Dwight; Christina Y Weng; Michal E Pawlowski; Tomasz S Tkaczyk
Journal:  Transl Vis Sci Technol       Date:  2019-06-21       Impact factor: 3.283

7.  Multispectral oximetry of murine tendon microvasculature with inflammation.

Authors:  Marieke A van der Putten; James M Brewer; Andrew R Harvey
Journal:  Biomed Opt Express       Date:  2017-05-08       Impact factor: 3.732

8.  In vivo absorption spectroscopy for absolute measurement.

Authors:  Hiromitsu Furukawa; Takashi Fukuda
Journal:  Biomed Opt Express       Date:  2012-09-18       Impact factor: 3.732

9.  Convolutional Neural Networks for Spectroscopic Analysis in Retinal Oximetry.

Authors:  Damon T DePaoli; Prudencio Tossou; Martin Parent; Dominic Sauvageau; Daniel C Côté
Journal:  Sci Rep       Date:  2019-08-06       Impact factor: 4.379

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.