Literature DB >> 18337886

Unbalanced versus balanced operation in an optical coherence tomography system.

A G Podoleanu1.   

Abstract

The choice of a balanced optical coherence tomography (OCT) configuration versus an unbalanced OCT configuration with optimized reference-arm attenuation is discussed. The choice depends on the receiver noise, the fiber-end reflection R, and the power to the object. When OCT is used to investigate biological tissue an equivalent R? can be evaluated as the compound reflected light from tissue. In this case an additional parameter has to be considered: the confocal optical sectioning interval of the OCT system.

Year:  2000        PMID: 18337886     DOI: 10.1364/ao.39.000173

Source DB:  PubMed          Journal:  Appl Opt        ISSN: 1559-128X            Impact factor:   1.980


  8 in total

1.  Characterization of Fourier domain mode-locked wavelength swept laser for optical coherence tomography imaging.

Authors:  Min Yong Jeon; Jun Zhang; Zhongping Chen
Journal:  Opt Express       Date:  2008-03-17       Impact factor: 3.894

2.  Nonlocal quantum macroscopic superposition in a high-thermal low-purity state.

Authors:  Mark E Brezinski; Bin Liu
Journal:  Phys Rev A       Date:  2008-12-16       Impact factor: 3.140

Review 3.  High-speed OCT light sources and systems [Invited].

Authors:  Thomas Klein; Robert Huber
Journal:  Biomed Opt Express       Date:  2017-01-13       Impact factor: 3.732

Review 4.  Optical coherence tomography: fundamental principles, instrumental designs and biomedical applications.

Authors:  Dan P Popescu; Lin-P'ing Choo-Smith; Costel Flueraru; Youxin Mao; Shoude Chang; John Disano; Sherif Sherif; Michael G Sowa
Journal:  Biophys Rev       Date:  2011-08-06

5.  Phase-stability optimization of swept-source optical coherence tomography.

Authors:  Sucbei Moon; Zhongping Chen
Journal:  Biomed Opt Express       Date:  2018-10-09       Impact factor: 3.732

6.  Laser applications and system considerations in ocular imaging.

Authors:  Ann E Elsner; Matthew S Muller
Journal:  Laser Photon Rev       Date:  2008-10-01       Impact factor: 13.138

7.  Demonstration of Shot-noise-limited Swept Source OCT Without Balanced Detection.

Authors:  Vala Fathipour; Tilman Schmoll; Alireza Bonakdar; Skylar Wheaton; Hooman Mohseni
Journal:  Sci Rep       Date:  2017-04-26       Impact factor: 4.379

8.  A Quantum Field Approach for Advancing Optical Coherence Tomography Part I: First Order Correlations, Single Photon Interference, and Quantum Noise.

Authors:  M E Brezinski
Journal:  J Lasers Opt Photonics       Date:  2017-12-30
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.