Literature DB >> 18336827

Enantiomeric resolution of bupivacaine by high-performance liquid chromatography and chiroptical detection.

F G Sánchez1, A N Díaz, A B M de Vicente.   

Abstract

This work reports a new analytical procedure for the separation and determination of the enantiomers of bupivacaine and the determination of the enantiomeric purity. The isomers were separated using a Chirex 3020 (250 mm x 4.6 mm) with a mobile phase of n-hexane:dichloroethane:ethanol (82:9:9, v/v/v) at a flow-rate of 1 ml min(-1) and UV, polarimetric and circular dichroism (CD) detection. Obtained retention times were 5.93 and 7.53 min (R and S) with a resolution of Rs=2.36. Precisions (RSD) were 1.83 and 2.02% (CD detection) and 3.07 and 1.26% (UV detection) for R- and S-enantiomers, respectively (at 10 microg level). Detection limits were 0.5 and 0.5 microg (R and S) with CD detection, and 0.9 and 0.3 microg with UV detection. Polarimetric detection was inadequate to perform a quantitative method at similar concentration ranges as UV and CD because of poor sensitivity. A procedure for determination of enantiomeric purity using a conventional chromatographic column (RP18, Luna) coupled to a CD detector and anisotropy factor (CD/UV) as analytical signal was also developed. Obtained results show that RSDs of 6.7-1.6% were obtained in the range of 0-100% enantiomeric purity.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18336827     DOI: 10.1016/j.chroma.2008.02.070

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  3 in total

1.  Lopinavir/ritonavir treatment increases the placental transfer of bupivacaine enantiomers in human immunodeficiency virus-infected pregnant women.

Authors:  Rodrigo Metzker Pereira Ribeiro; Fernanda de Lima Moreira; Elaine Christine Dantas Moisés; Ricardo Carvalho Cavalli; Silvana Maria Quintana; Vera Lucia Lanchote; Geraldo Duarte
Journal:  Br J Clin Pharmacol       Date:  2018-08-02       Impact factor: 4.335

2.  Determination of the enantiomeric purity of epinephrine by HPLC with circular dichroism detection.

Authors:  Douglas Kirkpatrick; Jingyue Yang; Michael Trehy
Journal:  J Liq Chromatogr Relat Technol       Date:  2017-05-31       Impact factor: 1.312

3.  Enantiomeric impurity analysis using circular dichroism spectroscopy with United States Pharmacopeia liquid chromatographic methods.

Authors:  Douglas Kirkpatrick; Margaret Fain; Jingyue Yang; Michael Trehy
Journal:  J Pharm Biomed Anal       Date:  2018-04-24       Impact factor: 3.935

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.