A study on the reconstruction of moderate contrast targets using the distorted born iterative method.

Roberto Lavarello1, Michael Oelze.   

Abstract

Previous tomographic methods using ultrasound for reconstructing sound speed and attenuation images suffered from convergence issues for targets with moderate speed of sound contrast. Convergence problems can be overcome by the use of the multiple frequency, distorted Born iterative method (DBIM). The implementation of DBIM for measurement configurations in which receiver positions are fixed was studied, and a novel regularization scheme was developed. The regularization parameter needed to stabilize the inversion process initially was found through the Rayleigh quotient iteration, then relaxed according to the relative residual error between the measured and estimated scattered fields. The DBIM was successfully stabilized for both full and partial receiver angular coverage without a significant loss in spatial resolution. The effects of variable density in the reconstructions were briefly explored through simulations. The ability to reconstruct targets with moderate contrast was validated through experimental measurements. Speed of sound profiles for balloons filled with saline in a background of water were reconstructed using multiple frequency DBIM techniques. The mean squared error for speed of sound reconstructions of the balloon phantoms with 16.4% sound speed contrast was 1.1%.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18334318     DOI: 10.1109/TUFFC.2008.621

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  9 in total

1.  Fast inverse scattering solutions using the distorted Born iterative method and the multilevel fast multipole algorithm.

Authors:  Andrew J Hesford; Weng C Chew
Journal:  J Acoust Soc Am       Date:  2010-08       Impact factor: 1.840

2.  A reconstruction algorithm of magnetoacoustic tomography with magnetic induction for an acoustically inhomogeneous tissue.

Authors:  Lian Zhou; Shanan Zhu; Bin He
Journal:  IEEE Trans Biomed Eng       Date:  2014-06       Impact factor: 4.538

3.  Tomographic density imaging using modified DF-DBIM approach.

Authors:  Tran Quang Huy; Nguyen Thi Cuc; Van Dung Nguyen; Ton That Long; Tran Duc Tan
Journal:  Biomed Eng Lett       Date:  2019-08-20

4.  3-D Nonlinear Acoustic Inverse Scattering: Algorithm and Quantitative Results.

Authors:  J W Wiskin; D T Borup; E Iuanow; J Klock; Mark W Lenox
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2017-05-23       Impact factor: 2.725

5.  A singular-value method for reconstruction of nonradial and lossy objects.

Authors:  Wei Jiang; Jeffrey Astheimer; Robert Waag
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2012-03       Impact factor: 2.725

6.  Deterministic compressive sampling for high-quality image reconstruction of ultrasound tomography.

Authors:  Tran Quang Huy; Huynh Huu Tue; Ton That Long; Tran Duc-Tan
Journal:  BMC Med Imaging       Date:  2017-05-25       Impact factor: 1.930

7.  Complementary use of priors for pulmonary imaging with electrical impedance and ultrasound computed tomography.

Authors:  Melody Alsaker; Diego Armando Cardona Cárdenas; Sérgio Shiguemi Furuie; Jennifer L Mueller
Journal:  J Comput Appl Math       Date:  2021-04-20       Impact factor: 2.872

8.  Quantitative transmission ultrasound tomography: Imaging and performance characteristics.

Authors:  Bilal Malik; Robin Terry; James Wiskin; Mark Lenox
Journal:  Med Phys       Date:  2018-05-28       Impact factor: 4.071

9.  Full wave 3D inverse scattering transmission ultrasound tomography in the presence of high contrast.

Authors:  James Wiskin; Bilal Malik; David Borup; Nasser Pirshafiey; John Klock
Journal:  Sci Rep       Date:  2020-11-19       Impact factor: 4.379

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.