Literature DB >> 1832634

Incidence of ultrasound-detected intrahepatic hematomas due to Tru-cut needle liver biopsy.

S Sugano1, Y Sumino, T Hatori, H Mizugami, T Kawafune, T Abei.   

Abstract

This is a prospective study in which 120 patients with diffuse liver disease undergoing liver biopsy were followed by serial ultrasounds to determine the incidence of postbiopsy intrahepatic hematoma formation. Forty-five of the patients had a blind biopsy, while the remaining 75 patients had a biopsy performed during laparoscopy. In both groups a 2.0-mm Tru-cut needle was employed. The overall incidence of postbiopsy hematoma formation was 18.3%, with approximately the same results occurring in blind biopsy patients (20%) and laparoscopy-guided biopsy patients (17%). Only two patients had significant pain associated with the hematoma formation (one from each group), one of whom had evidence of intraperitoneal bleed and rebleed. Our results suggest that postbiopsy asymptomatic hematomas occur more frequently than had been generally thought and that laparoscopy-guided biopsy is not safer than blind biopsy.

Entities:  

Mesh:

Year:  1991        PMID: 1832634     DOI: 10.1007/bf01307514

Source DB:  PubMed          Journal:  Dig Dis Sci        ISSN: 0163-2116            Impact factor:   3.199


  12 in total

Review 1.  Hepatic ultrasound.

Authors:  V N Igidbashian; L Jibin; B B Goldberg
Journal:  Semin Liver Dis       Date:  1989-02       Impact factor: 6.115

2.  Fatal hemorrhage from an arterio-portal-peritoneal fistula after percutaneous liver biopsy.

Authors:  J Korula; J Fried; M Weissman; G Greaney; C T Liew; E Finck
Journal:  Gastroenterology       Date:  1989-01       Impact factor: 22.682

3.  Computed tomography of the liver after biopsy.

Authors:  D E Malone; P A McCormick; D P O'Donoghue; D P MacErlean
Journal:  Clin Radiol       Date:  1987-01       Impact factor: 2.350

4.  Intrahepatic hematoma: a complication of percutaneous liver biopsy.

Authors:  D R Raines; R L Van Heertum; L F Johnson
Journal:  Gastroenterology       Date:  1974-08       Impact factor: 22.682

5.  Angiographic changes due to needle biopsy of the liver.

Authors:  S Wallace; H Medellin; R S Nelson
Journal:  Radiology       Date:  1972-10       Impact factor: 11.105

6.  Prospective study of the incidence of ultrasound-detected intrahepatic and subcapsular hematomas in patients randomized to 6 or 24 hours of bed rest after percutaneous liver biopsy.

Authors:  G Y Minuk; L R Sutherland; D A Wiseman; F R MacDonald; D L Ding
Journal:  Gastroenterology       Date:  1987-02       Impact factor: 22.682

7.  Delayed hemorrhage after percutaneous liver biopsy.

Authors:  C M Reichert; L M Weisenthal; H G Klein
Journal:  J Clin Gastroenterol       Date:  1983-06       Impact factor: 3.062

Review 8.  Sonographic findings in traumatic hemobilia: report of two cases and review of the literature.

Authors:  S L Sax; P A Athey; N Lamki; G A Cadavid
Journal:  J Clin Ultrasound       Date:  1988-01       Impact factor: 0.910

9.  Complications following percutaneous liver biopsy. A multicentre retrospective study on 68,276 biopsies.

Authors:  F Piccinino; E Sagnelli; G Pasquale; G Giusti
Journal:  J Hepatol       Date:  1986       Impact factor: 25.083

10.  Liver biopsy complications monitored by ultrasound.

Authors:  E Hederström; L Forsberg; C H Florén; H Prytz
Journal:  J Hepatol       Date:  1989-01       Impact factor: 25.083

View more
  7 in total

1.  A trucut biopsy needle for bipolar radiofrequency ablation of needle tract: a proof-of-concept experiment.

Authors:  Philipp Bruners; Tobias Penzkofer; Peter Isfort; Jochen Pfeffer; Thomas Schmitz-Rode; Rolf W Günther; Andreas H Mahnken
Journal:  Eur Radiol       Date:  2010-02-24       Impact factor: 5.315

2.  Liver biopsy: blind or guided?

Authors:  G Vautier; B Scott; D Jenkins
Journal:  BMJ       Date:  1994-12-03

3.  Transfemoral liver biopsy by forceps: a review of 104 consecutive procedures.

Authors:  J P Teare; A F Watkinson; S R Erb; J R Mayo; D G Connell; I H Weir; D A Owen; R Wolber; D C Morris
Journal:  Cardiovasc Intervent Radiol       Date:  1994 Sep-Oct       Impact factor: 2.740

4.  The safety of same-day endoscopy and percutaneous liver biopsy.

Authors:  Jonathan G Stine; Gordon Liss; James H Lewis
Journal:  Dig Dis Sci       Date:  2010-09-21       Impact factor: 3.199

5.  Safety of blind liver biopsy.

Authors:  A S M Bazlul Karim; Mizanur Rahman
Journal:  Indian J Pediatr       Date:  2004-10       Impact factor: 1.967

6.  Blind and ultrasound-guided percutaneous liver biopsy in children.

Authors:  Valerio Nobili; Donatella Comparcola; Maria Rita Sartorelli; Gianluigi Natali; Lidia Monti; Piergiorgio Falappa; Matilde Marcellini
Journal:  Pediatr Radiol       Date:  2003-09-05

7.  Radiofrequency cauterization with biopsy introducer needle.

Authors:  William F Pritchard; Diane Wray-Cahen; John W Karanian; Stephen Hilbert; Bradford J Wood
Journal:  J Vasc Interv Radiol       Date:  2004-02       Impact factor: 3.464

  7 in total