Literature DB >> 18325040

Evaluation of a novel internally controlled real-time PCR assay targeting the 16S rRNA gene for confirmation of Neisseria gonorrhoeae infections.

C Schabereiter-Gurtner1, P Hufnagl, G Sonvilla, B Selitsch, M L Rotter, A Makristathis, A M Hirschl.   

Abstract

A novel HybProbe real-time LightCycler PCR assay was developed for confirmation of Neisseria gonorrhoeae in samples positive according to the COBAS AMPLICOR Chlamydia trachomatis/Neisseria gonorrhoeae PCR assay. The new assay amplifies 375 bp of the N. gonorrhoeae 16S rRNA gene and includes an internal amplification control introduced during DNA purification. The assay had 100% specificity because of the high specificity of the HybProbes and primers. Other Neisseria spp. failed to generate positive crossing-point values and melting peaks. The analytical sensitivity for N. gonorrhoeae DNA was 0.5 fg/PCR, corresponding to 0.3 CFU/PCR. Sensitivity was not impaired in the presence of higher DNA concentrations (>or=1000-fold) from Neisseria spp. other than N. gonorrhoeae. The sensitivity was similar to that reported for the COBAS AMPLICOR assay with cervical swab samples. To assess its clinical applicability as a confirmatory test, 38 (2.9%) of 1313 swabs that were positive according to the COBAS AMPLICOR assay were tested using the new in-house assay and the commercially available GenFlow Neisseria test. Twenty-one samples negative according to COBAS AMPLICOR also underwent confirmatory testing. Both confirmatory tests yielded identical results; the 21 negative samples remained negative, and only 11 (28.9%) of the samples positive according to COBAS AMPLICOR were positive after retesting, suggesting a low prevalence (0.84%) of N. gonorrhoeae infection in the study population. These data suggest that the novel real-time PCR assay is an excellent and easy to interpret confirmatory test for the existing COBAS AMPLICOR assay for N. gonorrhoeae.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18325040     DOI: 10.1111/j.1469-0691.2008.01962.x

Source DB:  PubMed          Journal:  Clin Microbiol Infect        ISSN: 1198-743X            Impact factor:   8.067


  1 in total

1.  Rapid qualitative urinary tract infection pathogen identification by SeptiFast real-time PCR.

Authors:  Lutz E Lehmann; Stefan Hauser; Thomas Malinka; Sven Klaschik; Stefan U Weber; Jens-Christian Schewe; Frank Stüber; Malte Book
Journal:  PLoS One       Date:  2011-02-16       Impact factor: 3.240

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.