| Literature DB >> 18321509 |
Philipp Kobbe1, Ralf Klemm, Heinrich Reilmann, Thomas J Hockertz.
Abstract
Recent publications have reported encouraging results with a locked plating system in the management of periprosthetic femoral fractures. However, data on mid- or long-term functional outcome is not available. Here we report on the mid-term functional outcome of 16 patients with a periprosthetic femoral fracture following total hip arthroplasty managed with the LISS-system at a 3-year follow-up. Functional outcome was measured using the Harris Hip score and the Karnofsky activity index. The Harris Hip score and the Karnofsky activity index averaged 79.5 points and 81%, respectively. There were a total of two major complications due to screw pullout representing a complication rate of 13%. This series suggests that the management of periprosthetic femoral fractures with the LIS-System results in a good mid-term functional outcome.Entities:
Mesh:
Year: 2008 PMID: 18321509 DOI: 10.1016/j.injury.2007.10.034