Literature DB >> 18319089

Stress analysis of effects of nonrigid connectors on fixed partial dentures with pier abutments.

Selcuk Oruc1, Oguz Eraslan, H Alper Tukay, Arzu Atay.   

Abstract

STATEMENT OF PROBLEM: In some patients, the pattern of missing teeth may require the use of a fixed partial denture (FPD) with an intermediate pier abutment. Information is needed regarding the biomechanical behavior and the position of a nonrigid connector for this treatment option.
PURPOSE: The purpose of this study was to evaluate, by means of finite element method (FEM), the effects of rigid and nonrigid design types on stress distribution for 5-unit FPDs with pier abutments.
MATERIAL AND METHODS: A 3-dimensional cross-section FEM model (SAP 2000) simulating a 5-unit metal ceramic FPD with a pier abutment with rigid or nonrigid designs (connector location at the mesial region of the second molar, at the distal region of the second premolar, at the mesial region of the second premolar, and at the distal region of the canine) was developed. In the model, the canine, second premolar, and second molar served as abutments. A supporting periodontal ligament and alveolar bone (cortical and trabecular) were modeled. A 50-N static vertical occlusal load was applied on the cusp of each abutment to calculate the stress distributions. Three different types of load were evaluated: loading of all cusps to simulate maximum centric occlusion contacts, loading of the canine to simulate a single anterior contact, and loading of the second molar to simulate a posterior contact.
RESULTS: The analysis of the von Mises stress values revealed that maximum stress concentrations were located at the load areas for all models. Also, for all models, the highest stress values were located at connectors and cervical regions of abutment teeth, especially at the pier abutment.
CONCLUSIONS: The area of maximum stress concentration at the pier abutment was decreased by the use of a nonrigid connector at the distal region of the second premolar.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18319089     DOI: 10.1016/S0022-3913(08)60042-6

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  9 in total

1.  Non-Rigid Connector for Managing Pier Abutment in FPD: A Case Report.

Authors:  Ravikumar Suryakanth Akulwar; Ashwin Kodgi
Journal:  J Clin Diagn Res       Date:  2014-07-20

2.  Non-rigid connector: The wand to allay the stresses on abutment.

Authors:  Saurav Banerjee; Arlingstone Khongshei; Tapas Gupta; Ardhendu Banerjee
Journal:  Contemp Clin Dent       Date:  2011-10

3.  A three-dimension finite element analysis to evaluate the stress distribution in tooth supported 5-unit intermediate abutment prosthesis with rigid and nonrigid connector.

Authors:  Ritesh Modi; Shivani Kohli; K Rajeshwari; Shekhar Bhatia
Journal:  Eur J Dent       Date:  2015 Apr-Jun

4.  Effect of type of luting agents on stress distribution in the bone surrounding implants supporting a three-unit fixed dental prosthesis: 3D finite element analysis.

Authors:  Ehsan Ghasemi; Alireza Abedian; Pedram Iranmanesh; Saber Khazaei
Journal:  Dent Res J (Isfahan)       Date:  2015 Jan-Feb

5.  Three-dimensional finite element analysis of the stress distribution pattern in a mandibular first molar tooth restored with five different restorative materials.

Authors:  Kathleen Manuela D'souza; Meena Ajay Aras
Journal:  J Indian Prosthodont Soc       Date:  2017 Jan-Mar

6.  Fixed Functional Space Maintainer Incorporating a Tenon-Mortise Connector.

Authors:  Neil De Souza; Godwin Clovis Da Costa; Paul Chalakkal; Kennedy Mascarenhas
Journal:  Contemp Clin Dent       Date:  2018 Oct-Dec

7.  Comparative evaluation of frictional resistance of extracoronal attachments of different designs and lengths in fixed partial denture: A finite element analysis.

Authors:  Minal Sanjay Kumthekar; Pronob Kumar Sanyal; Shivsagar Tewary
Journal:  J Indian Prosthodont Soc       Date:  2021 Jan-Mar

8.  An Investigation of Three types of Tooth Implant Supported Fixed Prosthesis Designs with 3D Finite Element Analysis.

Authors:  Sara Koosha; Fatemeh Sadat Mirhashemi
Journal:  J Dent (Tehran)       Date:  2013-01-31

9.  Management of Partial Edentulism Using Nonrigid Connectors as a Treatment Modality: A Case Report.

Authors:  Sheela Sivakumar
Journal:  Cureus       Date:  2020-04-23
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.