Literature DB >> 18317639

Internal thoracic artery graft (ITAG): patency and functional status at rest and during dobutamine-stress echocardiography.

José Sebastião de Abreu1, Tereza Cristina Pinheiro Diógenes, André Luís de Castro Abreu, José Erirtônio Façanha Barreto, José Maria Bonfim de Morais, Marília Esther Benevides de Abreu, Jorge Henrique Azevedo Pinto, José Nogueira Paes Júnior.   

Abstract

BACKGROUND: The patent internal thoracic artery graft (ITAG) usually has a diastolic fraction (DF) > 50% of the flow. The functional assessment can be evaluated by the coronary reserve index (CRI).
OBJECTIVE: The objective was to evaluate the patency and functional status of the ITAG through echocardiography and Doppler.
METHODS: Data from sixty-six patients who underwent dobutamine-stress echocardiography (DSE) were prospectively collected and analyzed. Group I (GI) had 49 ITAG without stenosis, Group II (GII), 10 ITAG with significant stenosis (> 50% and <100%) and Group III (GIII) had 7 ITAG with total occlusion. Diameters and Doppler spectrums from the ITAG at rest and during DSE were evaluated.
RESULTS: Considering patency a DF >50%, it was observed in 49 ITAG (GI= 40, GII= 8 and GIII= 1) at rest and in 61 ITAG (GI=49, GII=10 and GIII=2) during DSE. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy were respectively, 81%, 86%, 98%, 35% and 82%, and 100%, at rest and 71%, 97%, 100% and 97% in the DSE. The ITAG with DF>50% at rest were patent and the ones with DF<50% in the DSE presented total occlusion. Considering a CRI>1.8 for a good functional status, it was observed in 42 ITAG (39 from GI, 2 from GII and 1 from GIII), determining sensitivity=79%, specificity=85.7%, PPV=94%, NPV=59% and accuracy= 80.9%. The CRI in GI was higher (p= 0.02) than in GII or GIII.
CONCLUSION: In our study, the non-invasive assessment of the ITAG was effective to verify the patency and the functional status.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18317639     DOI: 10.1590/s0066-782x2008000100007

Source DB:  PubMed          Journal:  Arq Bras Cardiol        ISSN: 0066-782X            Impact factor:   2.000


  2 in total

1.  Steal of blood flow from the vertebral artery to the internal thoracic artery anastomosed to the coronary artery.

Authors:  Jose Sebastião de Abreu; Nayara Lima Pimentel; Jordana Magalhães Siqueira; Carlos Newton Diógenes Pinheiro; Teresa Cristina Pinheiro Diógenes; José Nogueira Paes Junior
Journal:  Arq Bras Cardiol       Date:  2013-11       Impact factor: 2.000

2.  Coronary flow velocity reserve during dobutamine stress echocardiography.

Authors:  José Sebastião de Abreu; José Wellington Oliveira Lima; Tereza Cristina Pinheiro Diógenes; Jordana Magalhães Siqueira; Nayara Lima Pimentel; Pedro Sabino Gomes Neto; Marília Esther Benevides de Abreu; José Nogueira Paes Júnior
Journal:  Arq Bras Cardiol       Date:  2013-12-21       Impact factor: 2.000