Literature DB >> 18316186

Construction, electrochemically biosensing and discrimination of recombinant plasmid (pEThIL-2) on the basis of interleukine-2 DNA insert.

Mohammad Saeid Hejazi1, Mohammad Hossein Pournaghi-Azar, Esmaeel Alipour, Farrokh Karimi.   

Abstract

Construction, electrochemically biosensing and discrimination of recombinant pEThIL-2 plasmid, with 5839bp size, on the basis of interleukine-2 (IL-2) DNA insert are described. Plasmid pEThIL-2 was constructed by PCR amplification of IL-2 encoding DNA and subcloning into pET21a(+) vector using BamHI and SacI sites. The recombinant pEThIL-2 plasmid was detected with a label-free DNA hybridization biosensor using a non-inosine substituted probe. The proposed sensor was made up by immobilization of a 20-mer antisense single strand oligonucleotide (chIL-2) related to the human interleukine-2 gene on the pencil graphite electrode (PGE) as a probe and then the sensing of recombinant pEThIL-2 plasmid was conducted by anodic differential pulse voltammetry (ADPV) based on guanine oxidation signal. Selectivity of the detection was assessed with pET21a(+) non-complementary plasmid, with 5443bp size, lacking IL-2 encoding DNA. Different factors such as electrode activation conditions and washing strategy were tested in order to eliminate the nonspecific adsorption of pET21a(+). We have found that the PGE activation for 300s produces a condition in which desorption of nonspecifically adsorbed plasmids from the electrode surface can be achieved by 300s washing of the electrode in 20mM Tris-HCl buffer solution (pH 7.0) containing 20mM NaCl. Diagnostic performance of the biosensor is described and the detection limit is found to be 10.31pg/microL.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18316186     DOI: 10.1016/j.bios.2008.01.021

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  3 in total

1.  Label-free electrochemical detection of the specific oligonucleotide sequence of dengue virus type 1 on pencil graphite electrodes.

Authors:  Elaine Souza; Gustavo Nascimento; Nataly Santana; Danielly Ferreira; Manoel Lima; Edna Natividade; Danyelly Martins; José Lima-Filho
Journal:  Sensors (Basel)       Date:  2011-05-26       Impact factor: 3.576

2.  An improved electrochemical aptasensor for chloramphenicol detection based on aptamer incorporated gelatine.

Authors:  Ezat Hamidi-Asl; Freddy Dardenne; Ronny Blust; Karolien De Wael
Journal:  Sensors (Basel)       Date:  2015-03-27       Impact factor: 3.576

Review 3.  Advances in nanomaterials and their applications in point of care (POC) devices for the diagnosis of infectious diseases.

Authors:  Dai Thien Nhan Tram; Hao Wang; Sigit Sugiarto; Tao Li; Wee Han Ang; Chengkuo Lee; Giorgia Pastorin
Journal:  Biotechnol Adv       Date:  2016-09-26       Impact factor: 14.227

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.