Literature DB >> 18315376

Diagnosis of degenerative lesions of supraspinatus rotator cuff tendons by Fourier transform-Raman spectroscopy.

Sergio Camargo Godoy Penteado1, Bianca Palma Fogazza, Carolina da Silva Carvalho, Emilia Angela Loschiavo Arisawa, Mario Augusto Martins, Airton Abrahão Martin, Herculano da Silva Martinho.   

Abstract

The Fourier transform (FT)-Raman spectroscopy technique is used to assess the biochemical alterations that occur in the degenerative process of the rotator cuff supraspinatus tendon. The main alterations observed occur in the glycine, proline, hydroxyproline, cysteine, cistine, phenylalanine, tyrosine, collagen I and III, nucleic acid, lipids, glycosaminoglycans, and metalloproteinases bands. An increasing intensity for these bands is found in degenerated tendons, a finding well correlated with hyaline state and cellular activity. Statistical analysis (principal components analysis and clustering) shows a clear separation of the spectra into nonhyalinized and hyalinized clusters, which enables the construction of a binary diagnosis model based on logistic regression. Best diagnosis provided a sensitivity of 66.0% and a specificity of 74.7% with 79.6% concordant pairs. The discriminating power of the diagnostic test is assessed by computing the area under the receiving-operator characteristic curve (AUC), which indicates good accuracy (AUC=0.81). In principle, these results indicate that Raman spectroscopy can be used as an auxiliary aid to improve shoulder tendon surgery quality by guiding anchoring onto more healthy (nonhyaline) pieces of tendons. This should contribute to a decrease in the current high rerupture rate (13 to 68%) for this procedure.

Entities:  

Mesh:

Year:  2008        PMID: 18315376     DOI: 10.1117/1.2841017

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  4 in total

Review 1.  Raman spectroscopy of soft musculoskeletal tissues.

Authors:  Karen Esmonde-White
Journal:  Appl Spectrosc       Date:  2014-10-01       Impact factor: 2.388

2.  Effects of low-power LED and therapeutic ultrasound in the tissue healing and inflammation in a tendinitis experimental model in rats.

Authors:  Manoel de Jesus Moura Júnior; Emilia Ângela Loschiavo Arisawa; Airton Abrahão Martin; Janderson Pereira de Carvalho; José Mário Nunes da Silva; José Figueiredo Silva; Landulfo Silveira
Journal:  Lasers Med Sci       Date:  2013-05-10       Impact factor: 3.161

3.  DNA Extraction Systematics for Spectroscopic Studies.

Authors:  Bianca Fogazza Palma; Amanda Borges Ferrari; Renata Andrade Bitar; Maria Angélica Gargione Cardoso; Airton A Martin; Herculano Da Silva Martinho
Journal:  Sensors (Basel)       Date:  2008-06-01       Impact factor: 3.576

4.  Detection of Age-Related Changes in Tendon Molecular Composition by Raman Spectroscopy-Potential for Rapid, Non-Invasive Assessment of Susceptibility to Injury.

Authors:  Nai-Hao Yin; Anthony W Parker; Pavel Matousek; Helen L Birch
Journal:  Int J Mol Sci       Date:  2020-03-20       Impact factor: 5.923

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.