Literature DB >> 18313355

Transcranial magnetic stimulation reduces masseter motoneuron pool excitability throughout the cortical silent period.

Paul F Sowman1, Stanley C Flavel, Christie L McShane, Timothy S Miles, Michael A Nordstrom.   

Abstract

OBJECTIVE: To evaluate the time-course of changes in masseter motoneuron pool excitability following transcranial magnetic stimulation of motor cortex, and relate this to the duration of the masseter cortical silent period (CSP).
METHODS: Surface EMG was recorded bilaterally from masseter and digastric muscles in 13 subjects. Focal TMS was applied at 1.3x active motor threshold (AMT) to motor cortex of one hemisphere to elicit a muscle evoked potential (MEP) and silent period bilaterally in masseter as subjects maintained an isometric bite at approximately 10% maximum. With jaw muscles relaxed, a servo-controlled stretcher evoked a stretch reflex in masseter which was conditioned by TMS (1.3x AMT) at 14 different conditioning-testing intervals. There were 20 trials at each interval, in random order. TMS evoked no MEP in resting masseter, but often produced a small MEP in digastric.
RESULTS: Mean (+/-SE) masseter CSP was 67+/-3ms. The masseter stretch reflex was facilitated when stretch preceded TMS by 8 and 10ms, which we attribute to spatial summation of corticobulbar and Ia-afferent excitatory inputs to masseter. Masseter stretch reflex amplitude was reduced when TMS was given up to 75ms before stretch, and for up to 2ms afterwards.
CONCLUSIONS: We conclude that descending corticobulbar activity evoked by TMS acts bilaterally on brainstem interneurons that either inhibit masseter motoneurons or increase pre-synaptic inhibition of Ia-afferent terminals for up to 75ms after TMS. The reduction of masseter motoneuron pool excitability following TMS has a similar time-course to the CSP. SIGNIFICANCE: In contrast to the situation for spinal and facial (CN VII) muscles, the masseter CSP appears to have no component that can be attributed exclusively to cortical mechanisms. Abnormalities in the masseter cortical silent period observed in neurological conditions may be due to pathophysiological changes at cortical and/or sub-cortical levels.

Mesh:

Year:  2008        PMID: 18313355     DOI: 10.1016/j.clinph.2007.12.019

Source DB:  PubMed          Journal:  Clin Neurophysiol        ISSN: 1388-2457            Impact factor:   3.708


  9 in total

1.  Vocal response inhibition is enhanced by anodal tDCS over the right prefrontal cortex.

Authors:  Leidy J Castro-Meneses; Blake W Johnson; Paul F Sowman
Journal:  Exp Brain Res       Date:  2015-09-29       Impact factor: 1.972

2.  Intracortical modulation of cortical-bulbar responses for the masseter muscle.

Authors:  Enzo Ortu; Franca Deriu; Antonio Suppa; Elena Giaconi; Eusebio Tolu; John C Rothwell
Journal:  J Physiol       Date:  2008-05-22       Impact factor: 5.182

3.  Cortical Silent Period Reveals Differences Between Adductor Spasmodic Dysphonia and Muscle Tension Dysphonia.

Authors:  Sharyl Samargia; Rebekah Schmidt; Teresa Jacobson Kimberley
Journal:  Neurorehabil Neural Repair       Date:  2015-06-18       Impact factor: 3.919

4.  Jaw-opening reflex and corticobulbar motor excitability changes during quiet sleep in non-human primates.

Authors:  Dongyuan Yao; Gilles J Lavigne; Jye-Chang Lee; Kazunori Adachi; Barry J Sessle
Journal:  Sleep       Date:  2013-02-01       Impact factor: 5.849

5.  Sensorimotor modulation differs with load type during constant finger force or position.

Authors:  Hikari Kirimoto; Hiroyuki Tamaki; Makoto Suzuki; Takuya Matsumoto; Kazuhiro Sugawara; Syo Kojima; Hideaki Onishi
Journal:  PLoS One       Date:  2014-09-18       Impact factor: 3.240

6.  Evaluation of silent period on masticatory cycles of different muscles in dentate oral contraceptives users and nonusers.

Authors:  Karina Helga Leal Turcio; Alício Rosalino Garcia; Paulo Renato Junqueira Zuim; Amália Moreno; Marcelo Coelho Goiato; Aimée Maria Guiotti; Daniela Micheline Dos Santos
Journal:  Eur J Dent       Date:  2015 Apr-Jun

7.  The effects of impulsivity and proactive inhibition on reactive inhibition and the go process: insights from vocal and manual stop signal tasks.

Authors:  Leidy J Castro-Meneses; Blake W Johnson; Paul F Sowman
Journal:  Front Hum Neurosci       Date:  2015-10-06       Impact factor: 3.169

8.  Short-term effects of repetitive transcranial magnetic stimulation on sleep bruxism - a pilot study.

Authors:  Wei-Na Zhou; Hai-Yang Fu; Yi-Fei Du; Jian-Hua Sun; Jing-Lu Zhang; Chen Wang; Peter Svensson; Ke-Lun Wang
Journal:  Int J Oral Sci       Date:  2016-03-30       Impact factor: 6.344

9.  Stop signals delay synchrony more for finger tapping than vocalization: a dual modality study of rhythmic synchronization in the stop signal task.

Authors:  Leidy J Castro-Meneses; Paul F Sowman
Journal:  PeerJ       Date:  2018-07-12       Impact factor: 2.984

  9 in total