Literature DB >> 18313212

Improved derivatisation methods for the determination of free cyanide and cyanate in mine effluent.

Caliphs M Zvinowanda1, Jonathan O Okonkwo, Rogers C Gurira.   

Abstract

Generally, the level of cyanide in waste effluents is too high to be discharged into the environment. Consequently, treatment regimes are necessary in order to protect the environment. However, the cost of most of the treatment methods is expensive and not sensitive enough and, therefore, cannot always be justified. In this research, cyanide speciation products, free cyanide (CN(-)) and cyanate (CNO(-)) were determined by highly sensitive derivatisation methods followed by spectrometric analysis. Spectral scans were carried out for pure and environmental samples derivatives in order to evaluate the possibility of interfering species. For CN(-) a linear range from 0.01 to 80.0mg/L was determined. In the case of CNO(-), the linear range was between 0.02 and 80.0mg/L. The detection limits were 0.05 and 0.20mg/L for CN(-) and CNO(-), respectively. These values are in good agreement with those reported in literature. The concentration ranges of the speciation products in environmental samples were 0.70-52.0mg/L and 0.50-76.0mg/L for CN(-) and CNO(-), respectively. These values were well above their acute toxicity levels. Increase in cyanate levels in the effluent with time was clearly observed while the concentration of cyanide decreased. This was attributed to the oxidation of CN(-) to CNO(-).

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18313212     DOI: 10.1016/j.jhazmat.2008.01.059

Source DB:  PubMed          Journal:  J Hazard Mater        ISSN: 0304-3894            Impact factor:   10.588


  3 in total

1.  Assessment of water quality parameters in the stream Galyan, Trabzon, Turkey.

Authors:  V Numan Bulut; Adem Bayram; Ali Gundogdu; Mustafa Soylak; Mehmet Tufekci
Journal:  Environ Monit Assess       Date:  2009-04-29       Impact factor: 2.513

Review 2.  Recent developments in cyanide detection: a review.

Authors:  Jian Ma; Purnendu K Dasgupta
Journal:  Anal Chim Acta       Date:  2010-06-04       Impact factor: 6.558

3.  Pyrene-Hydrazone-π···Hole Coupled Turn-on Fluorescent and Naked- Eye Colorimetric Sensor for Cyanide: Role of Homogeneous π-Hole Dispersion in Anion Selectivity.

Authors:  Vanthana Jeyasingh; Kumaresan Murugesan; Sudha Lakshminarayanan; Narayanan Selvapalam; Geetha Das; Lakshminarayanan Piramuthu
Journal:  J Fluoresc       Date:  2021-06-10       Impact factor: 2.217

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.