BACKGROUND: The aims of this study are to evaluate and compare the accuracies of isotropic multi-detector row CT (MDCT) including multiplanar reconstruction (MPR) images for preoperative staging of endoscopically diagnosed early gastric cancer (eEGC) and advanced gastric cancer (eAGC). METHODS: One hundred and five patients with endoscopically proven gastric cancer underwent isotropic MDCT. Three independent radiologists evaluated T and N staging both on transverse images only and on three orthogonal MPR images. The staging of each tumor was surgico-pathologically confirmed. The receiver operating characteristic (ROC) analysis and the Wilcoxon signed ranked test were used for statistical analyses. RESULTS: In 30 eAGCs, the accuracies for T and N staging with MPR imaging were better than those with transverse imaging (each P < 0.05). In 34 eEGCs, however, only the accuracy of T2 or higher with MPR imaging was higher than that with transverse imaging (P < 0.05). CONCLUSIONS: Isotropic MDCT with MPR images including coronal or sagittal reconstructions can improve the accuracies of preoperative T and N staging of eAGC, while having little impact on the accuracy for eEGC.
BACKGROUND: The aims of this study are to evaluate and compare the accuracies of isotropic multi-detector row CT (MDCT) including multiplanar reconstruction (MPR) images for preoperative staging of endoscopically diagnosed early gastric cancer (eEGC) and advanced gastric cancer (eAGC). METHODS: One hundred and five patients with endoscopically proven gastric cancer underwent isotropic MDCT. Three independent radiologists evaluated T and N staging both on transverse images only and on three orthogonal MPR images. The staging of each tumor was surgico-pathologically confirmed. The receiver operating characteristic (ROC) analysis and the Wilcoxon signed ranked test were used for statistical analyses. RESULTS: In 30 eAGCs, the accuracies for T and N staging with MPR imaging were better than those with transverse imaging (each P < 0.05). In 34 eEGCs, however, only the accuracy of T2 or higher with MPR imaging was higher than that with transverse imaging (P < 0.05). CONCLUSIONS: Isotropic MDCT with MPR images including coronal or sagittal reconstructions can improve the accuracies of preoperative T and N staging of eAGC, while having little impact on the accuracy for eEGC.
Authors: Ki Jeong Park; Min Woo Lee; Ji Hyun Koo; Yulri Park; Heejung Kim; Dongil Choi; Soon Jin Lee Journal: World J Gastroenterol Date: 2011-02-28 Impact factor: 5.742
Authors: M Anzidei; A Napoli; F Zaccagna; P Di Paolo; C Zini; B Cavallo Marincola; D Geiger; C Catalano; R Passariello Journal: Radiol Med Date: 2009-09-22 Impact factor: 3.469
Authors: James T P D Hallinan; Sudhakar K Venkatesh; Luke Peter; Andrew Makmur; Wei Peng Yong; Jimmy B Y So Journal: Eur Radiol Date: 2014-07-21 Impact factor: 5.315