| Literature DB >> 18309380 |
Aaron A Hofmann1, Michael Bolognesi, Amit Lahav, Stephen Kurtin.
Abstract
Leg-length inequality after total hip arthroplasty remains a controversial issue. In the study reported here, we sought to determine whether significant leg-length discrepancies (> 6 mm) can be minimized with use of an intraoperative x-ray. In each case, preoperative templating was carefully performed, an intraoperative pelvis x-ray was obtained to assess accuracy, and appropriate adjustments were made. Eighty-six consecutive primary total hip arthroplasties and their associated x-rays were retrospectively reviewed. Mean postoperative leg-length discrepancy was 0.3 mm (SD, 2.6 mm; range, -6 to +6 mm). No legs were lengthened or shortened by more than 6 mm. Significant leg-length discrepancies can be minimized with use of an intraoperative pelvis x-ray.Entities:
Mesh:
Year: 2008 PMID: 18309380
Source DB: PubMed Journal: Am J Orthop (Belle Mead NJ) ISSN: 1078-4519