Literature DB >> 18306375

Extending the range of diffusion times for regional measurement of the 3He ADC in human lungs.

Chengbo Wang1, G Wilson Miller, Talissa A Altes, Eduard E de Lange, Gordon D Cates, Jaime F Mata, James R Brookeman, John P Mugler.   

Abstract

A stimulated-echo-based technique was developed to measure the regional apparent diffusion coefficient (ADC) of hyperpolarized 3He during a single breathhold for diffusion times of 25 ms or greater. Compared to previous methods, a substantially shorter minimum diffusion time was achieved by decoupling diffusion sensitization from image acquisition. A hyperpolarized-gas phantom was used to validate the method, which was then tested in four healthy subjects in whom regional ADC maps were acquired with diffusion times of 50, 200, and 1500 ms and a tag wavelength of 5 or 10 mm. ADC values from healthy subjects were in good agreement with reported literature values and decreased with increasing diffusion time. Mean ADC values were approximately 0.07, 0.03, and 0.015 cm2/s for diffusion times of 50, 200, and 1500 ms, respectively. ADC maps were generally homogeneous, with similar mean values when measured with the same parameters in different subjects. (c) 2008 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18306375     DOI: 10.1002/mrm.21543

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  4 in total

1.  Optically polarized 3He.

Authors:  T R Gentile; P J Nacher; B Saam; T G Walker
Journal:  Rev Mod Phys       Date:  2017-12-11       Impact factor: 54.494

Review 2.  Imaging of lung function using hyperpolarized helium-3 magnetic resonance imaging: Review of current and emerging translational methods and applications.

Authors:  Sean Fain; Mark L Schiebler; David G McCormack; Grace Parraga
Journal:  J Magn Reson Imaging       Date:  2010-12       Impact factor: 4.813

Review 3.  Pulmonary CT and MRI phenotypes that help explain chronic pulmonary obstruction disease pathophysiology and outcomes.

Authors:  Eric A Hoffman; David A Lynch; R Graham Barr; Edwin J R van Beek; Grace Parraga
Journal:  J Magn Reson Imaging       Date:  2015-07-22       Impact factor: 4.813

4.  Detecting pulmonary capillary blood pulsations using hyperpolarized xenon-129 chemical shift saturation recovery (CSSR) MR spectroscopy.

Authors:  Kai Ruppert; Talissa A Altes; Jaime F Mata; Iulian C Ruset; F William Hersman; John P Mugler
Journal:  Magn Reson Med       Date:  2015-05-28       Impact factor: 4.668

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.