Visualization of the biliary tract using gadobenate dimeglumine: preliminary findings.

Fatma Bilge Ergen1, Deniz Akata, Basar Sarikaya, Ulku Kerimoglu, Mutlu Hayran, Okan Akhan, Hero K Hussain.   

Abstract

OBJECTIVE: To compare contrast-enhanced magnetic resonance (MR) cholangiography (CE-MRC) performed with gadobenate dimeglumine with T2-weighted MRC (T2-MRC) for visualization of the bile ducts in nondilated biliary systems.
MATERIALS AND METHODS: Twenty consecutive patients who underwent MR imaging (MRI) of the liver and pancreas with nondilated intrahepatic ducts were included in this retrospective study. T2-weighted MRC was performed using a multislice, high-resolution fat-suppressed half-Fourier acquisition turbo spin-echo sequence. Contrast-enhanced MR cholangiography was performed using a fat-suppressed 3-dimensional fast low-angle shot sequence acquired 1 to 1.5 hour after intravenous administration of gadobenate dimeglumine. For image interpretation, the biliary system was divided into 8 segments. Two readers graded visualization of each segment on T2-MRC and CE-MRC using a 5-point scale (0, nonvisualization; 4, excellent visualization). Final opinion for each sequence was rendered by consensus. Superiority of visualization was assessed using the McNemar test and comparing adequately (visualization scores 3 and 4) and inadequately (visualization scores 0, 1, and 2) visualized segments of the ducts on both sequences. Interobserver variability was assessed with kappa statistics.
RESULTS: Overall and segment-based evaluation revealed superior visualization of biliary segments with CE-MRC compared with T2-MRC. We also found a statistically significant difference between the 2 sequences for overall and for right hepatic duct and cystic channel visualization (P < 0.05). A high concordance between readers 1 and 2 both for T2-MRC and CE-MRC was achieved (85.8% and 89.4%, respectively).
CONCLUSIONS: Gadobenate dimeglumine can be used as an alternative intrabiliary contrast agent for contrast-enhanced MR cholangiography in nondilated biliary systems in patients with normal excretory liver function tests.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18303288     DOI: 10.1097/RCT.0b013e3180616b87

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  8 in total

1.  Gd-BOPTA-enhanced MR cholangiography findings in gall bladder perforation.

Authors:  Oktay Algin; Nuraydin Ozlem; Evrim Kilic; Mustafa Karaoglanoglu; Halil Arslan
Journal:  Emerg Radiol       Date:  2010-06-29

2.  Confident diagnosis of bronchobiliary fistula using contrast-enhanced magnetic resonance cholangiography.

Authors:  Nevzat Karabulut; Vefa Cakmak; Göksel Kiter
Journal:  Korean J Radiol       Date:  2010-06-21       Impact factor: 3.500

Review 3.  Hepatobiliary MR imaging with gadolinium-based contrast agents.

Authors:  Alex Frydrychowicz; Meghan G Lubner; Jeffrey J Brown; Elmar M Merkle; Scott K Nagle; Neil M Rofsky; Scott B Reeder
Journal:  J Magn Reson Imaging       Date:  2012-03       Impact factor: 4.813

4.  Peritoneal and pleural fluids may appear hyperintense on hepatobiliary phase using hepatobiliary MR contrast agents.

Authors:  Maria Ciolina; Michele Di Martino; Onorina Bruno; Romain Pommier; Valérie Vilgrain; Maxime Ronot
Journal:  Eur Radiol       Date:  2018-01-26       Impact factor: 5.315

Review 5.  Magnetic resonance cholangiography in the assessment and management of biliary complications after OLT.

Authors:  Rossano Girometti; Lorenzo Cereser; Massimo Bazzocchi; Chiara Zuiani
Journal:  World J Radiol       Date:  2014-07-28

Review 6.  [Passive and active magnetic resonance cholangiopancreatography : Technique, indications, and typical anatomy].

Authors:  J Vosshenrich; D T Boll; C J Zech
Journal:  Radiologe       Date:  2019-04       Impact factor: 0.635

7.  Non-invasive detection of biliary leaks using Gd-EOB-DTPA-enhanced MR cholangiography: comparison with T2-weighted MR cholangiography.

Authors:  Mecit Kantarcı; Berhan Pirimoglu; Nevzat Karabulut; Ummugulsum Bayraktutan; Hayri Ogul; Gurkan Ozturk; Bulent Aydinli; Yesim Kizrak; Suat Eren; Sinan Yilmaz
Journal:  Eur Radiol       Date:  2013-05-22       Impact factor: 5.315

8.  Detection and characterization of traumatic bile leaks using Gd-EOB-DTPA enhanced magnetic resonance cholangiography.

Authors:  Yon-Cheong Wong; Li-Jen Wang; Cheng-Hsien Wu; Huan-Wu Chen; Chen-Ju Fu; Kuo-Ching Yuan; Being-Chuan Lin; Yu-Pao Hsu; Shih-Ching Kang
Journal:  Sci Rep       Date:  2018-10-02       Impact factor: 4.379