Literature DB >> 18301891

Effects of bacteria and yeast on WBC counting in three automated hematology counters.

Hye Ryoun Kim1, Bo Rae G Park, Mi Kyung Lee.   

Abstract

Bacteria or yeast may be observed on peripheral blood smears and may lead to spuriously elevated platelet counts. They have been reported to disturb the white blood cell (WBC) differential count if they clumped together, and a large number of such microorganisms have been shown to increase WBC counts. The purpose of this study was to evaluate the spurious rise in WBC counts according to species of microorganisms and automated hematology analyzers. The species we selected were Staphylococcus aureus, Escherichia coli, Candida albicans, C. tropicalis, C. krusei, C. dubliniensis, C. glabrata, and C. parapsilosis. We investigated the effects of bacteria and yeast on peripheral blood samples by the ADVIA 120/2120 Hematology System, Sysmex XE-2100 (TOA Medical Electronics, Kobe, Japan) and Coulter LH 750 (Beckman Coulter, Miami, FL, USA). C. albicans, C. tropicalis, C. krusei, and C. dubliniensis had an overt effect on the WBC count at concentrations of up to 1-5 x 10(7) colony-forming units (CFU)/mL in three automated cell counters, and C. glabrata and C. parapsilosis, when present at concentrations of 1-5 x 10(8) CFU/mL, caused a significant increase in the WBC count obtained by the Sysmex XE-2100 but not by the ADVIA 120/2120 system and Coulter LH 750 (p < 0.05). In conclusion, yeast may influence the results of peripheral blood smears only when the yeast concentration is unusually high. The results differed among analyzers and among species of yeast. Hematologists should be aware that samples containing bacteria and yeast may give erroneously high WBC counts and differential leukocyte counts and should review the peripheral blood smear by microscopy.

Entities:  

Mesh:

Year:  2008        PMID: 18301891     DOI: 10.1007/s00277-008-0464-1

Source DB:  PubMed          Journal:  Ann Hematol        ISSN: 0939-5555            Impact factor:   3.673


  5 in total

1.  Automated Cerebrospinal Fluid Cell Counts Using the New Body Fluid Mode of Sysmex UF-1000i.

Authors:  Sabrina Buoro; Sara Apassiti Esposito; MariaGrazia Alessio; Alberto Crippa; Cosimo Ottomano; Giuseppe Lippi
Journal:  J Clin Lab Anal       Date:  2015-08-24       Impact factor: 2.352

Review 2.  Candidemia Diagnosed from Peripheral Blood Smear: Case Report and Review of Literature 1954-2013.

Authors:  Yuji Hirai; Sayaka Asahata; Yusuke Ainoda; Takahiro Fujita; Hitomi Miura; Naomi Hizuka; Ken Kikuchi
Journal:  Mycopathologia       Date:  2015-04-08       Impact factor: 2.574

Review 3.  Automated haematology analysis to diagnose malaria.

Authors:  Germán Campuzano-Zuluaga; Thomas Hänscheid; Martin P Grobusch
Journal:  Malar J       Date:  2010-11-30       Impact factor: 2.979

Review 4.  Unreliable Automated Complete Blood Count Results: Causes, Recognition, and Resolution.

Authors:  Gene Gulati; Guldeep Uppal; Jerald Gong
Journal:  Ann Lab Med       Date:  2022-09-01       Impact factor: 4.941

Review 5.  Purpose and criteria for blood smear scan, blood smear examination, and blood smear review.

Authors:  Gene Gulati; Jinming Song; Alina Dulau Florea; Jerald Gong
Journal:  Ann Lab Med       Date:  2012-12-17       Impact factor: 3.464

  5 in total