Quality by design, part I: application of NIR spectroscopy to monitor tablet manufacturing process.

Simin Hassannejad Tabasi1, Raafat Fahmy, Dennis Bensley, Charles O'Brien, Stephen W Hoag.   

Abstract

To monitor tableting production using near infrared (NIR) spectroscopy, chemometric models were developed to analyze peak compression force, crushing strength and content uniformity. To measure tablet content uniformity, orbifloxacin tablets with drug content ranging from 60 to 90 mg were made and analyzed using ultraviolet (UV) and NIR spectroscopy. To assess the compression force and crushing strength, several batches of tablets were made on a Stokes B2 rotary tablet press and compression force was varied from 360 to 3500 lb. Principal component analysis (PCA) was used to identify tablets with regular and capped tablets breakage patterns. Comparison of statistical parameters showed that partial least squares (PLS) models gave better fit than the multiple linear regression (MLR) models. The best fit PLS models had a standard error of calibration (SEC) and a standard error of prediction (SEP) for content uniformity of 1.13 and 1.36 mg; for compression force of 69.86 and 59.48 lb and for crushing strength 0.55 kP and 0.57 kP, respectively. NIR spectroscopy in combination with multivariate modeling is a rapid and nondestructive technique that could reliably predict content uniformity, compression force and crushing strength for orbifloxacin tablets.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18300297     DOI: 10.1002/jps.21303

Source DB:  PubMed          Journal:  J Pharm Sci        ISSN: 0022-3549            Impact factor:   3.534


  5 in total

1.  Inline real-time near-infrared granule moisture measurements of a continuous granulation-drying-milling process.

Authors:  Lipika Chablani; Michael K Taylor; Amit Mehrotra; Patrick Rameas; William C Stagner
Journal:  AAPS PharmSciTech       Date:  2011-08-13       Impact factor: 3.246

2.  Quality-by-design III: application of near-infrared spectroscopy to monitor roller compaction in-process and product quality attributes of immediate release tablets.

Authors:  Ravikanth Kona; Raafat M Fahmy; Gregg Claycamp; James E Polli; Marilyn Martinez; Stephen W Hoag
Journal:  AAPS PharmSciTech       Date:  2014-10-16       Impact factor: 3.246

3.  Fast tablet tensile strength prediction based on non-invasive analytics.

Authors:  Anna Halenius; Satu Lakio; Osmo Antikainen; Juha Hatara; Jouko Yliruusi
Journal:  AAPS PharmSciTech       Date:  2014-03-18       Impact factor: 3.246

Review 4.  Pharmaceutical application of multivariate modelling techniques: a review on the manufacturing of tablets.

Authors:  Guolin Shi; Longfei Lin; Yuling Liu; Gongsen Chen; Yuting Luo; Yanqiu Wu; Hui Li
Journal:  RSC Adv       Date:  2021-02-23       Impact factor: 3.361

Review 5.  Process Analytical Technology Tools for Monitoring Pharmaceutical Unit Operations: A Control Strategy for Continuous Process Verification.

Authors:  Eun Ji Kim; Ji Hyeon Kim; Min-Soo Kim; Seong Hoon Jeong; Du Hyung Choi
Journal:  Pharmaceutics       Date:  2021-06-21       Impact factor: 6.321

  5 in total