Literature DB >> 1830004

Technetium 99m SESTAMIBI myocardial perfusion imaging: comparison between treadmill, dipyridamole and trans-oesophageal atrial pacing "stress" tests in normal subjects.

M Primeau1, R Taillefer, R Essiambre, R Lambert, G Honos.   

Abstract

The purpose of this study was to determine the blood clearance, myocardial uptake and heart/lung and heart/liver ratios of technetium 99m methoxyisobutylisonitrile (99mTc-SESTAMIBI) following 3 different types of cardiac stimulation in normal subjects: treadmill stress (STRESS), intravenous administration of dipyridamole (DIP) and trans-oesophageal atrial pacing (TAP). Ten normal volunteers were submitted to 3 injections of 99mTc-SESTAMIBI (10 mCi/70 kg, separated by an interval of 7 days) following STRESS (standard Bruce protocol), DIP (0.142 mg/kg.min during 4 min) and TAP procedures. Blood samples were collected from 1 to 60 min after each 99mTc-SESTAMIBI injection. Planar imaging was performed at 5, 30 and 60 min. Blood retention (percentage of injected dose at 1 min) was 56% +/- 4%, 24% +/- 4% and 38% +/- 6% for STRESS, DIP and TAP, respectively (P less than 0.001). Myocardial uptake was similar for the 3 procedures while the heart lung ratio at 60 min was 3.1 +/- 0.5, 3.8 +/- 0.6 and 3.2 +/- 0.5 for STRESS, DIP and TAP, respectively. Heart/liver ratio at 60 min was 1.9 +/- 0.5, 1.3 +/- 0.3 and 1.1 +/- 0.2 for STRESS, DIP and TAP, respectively (P less than 0.001). These results demonstrated that the 3 types of cardiac stimulation show good imaging parameters with 99mTc-SESTA-MIBI.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1830004     DOI: 10.1007/bf00186648

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  17 in total

1.  The utilization of Tc-99m-TBI as a myocardial perfusion agent in exercise studies: comparison with Tl-201 thallous chloride and examination of its biodistribution in humans.

Authors:  S T Sia; B L Holman; K McKusick; P Rigo; F Gillis; V Sporn; N Perez-Balino; A Mitta; H Vosberg; Z Szabo
Journal:  Eur J Nucl Med       Date:  1986

2.  Transesophageal electrocardiography and cardiac pacing: state of the art.

Authors:  D W Benson
Journal:  Circulation       Date:  1987-04       Impact factor: 29.690

3.  The pacing stress test: thallium-201 myocardial imaging after atrial pacing. Diagnostic value in detecting coronary artery disease compared with exercise testing.

Authors:  G V Heller; J M Aroesty; J A Parker; R G McKay; K J Silverman; A V Als; P C Come; G M Kolodny; W Grossman
Journal:  J Am Coll Cardiol       Date:  1984-05       Impact factor: 24.094

Review 4.  Exercise radionuclide imaging approaches to coronary artery disease.

Authors:  R D Okada; C A Boucher; H W Strauss; G M Pohost
Journal:  Am J Cardiol       Date:  1980-12-18       Impact factor: 2.778

5.  Dipyridamole-thallium-201 scintigraphy in the prediction of future cardiac events after acute myocardial infarction.

Authors:  J A Leppo; J O'Brien; J A Rothendler; J D Getchell; V W Lee
Journal:  N Engl J Med       Date:  1984-04-19       Impact factor: 91.245

6.  Differentiation of transiently ischemic from infarcted myocardium by serial imaging after a single dose of thallium-201.

Authors:  G M Pohost; L M Zir; R H Moore; K A McKusick; T E Guiney; G A Beller
Journal:  Circulation       Date:  1977-02       Impact factor: 29.690

7.  Serial thallium-201 myocardial imaging after dipyridamole infusion: diagnostic utility in detecting coronary stenoses and relationship to regional wall motion.

Authors:  J Leppo; C A Boucher; R D Okada; J B Newell; H W Strauss; G M Pohost
Journal:  Circulation       Date:  1982-09       Impact factor: 29.690

8.  Prediction of cardiac events after uncomplicated myocardial infarction: a prospective study comparing predischarge exercise thallium-201 scintigraphy and coronary angiography.

Authors:  R S Gibson; D D Watson; G B Craddock; R S Crampton; D L Kaiser; M J Denny; G A Beller
Journal:  Circulation       Date:  1983-08       Impact factor: 29.690

9.  Prognostic value of exercise thallium-201 imaging in patients presenting for evaluation of chest pain.

Authors:  K A Brown; C A Boucher; R D Okada; T E Guiney; J B Newell; H W Strauss; G M Pohost
Journal:  J Am Coll Cardiol       Date:  1983-04       Impact factor: 24.094

10.  Diagnostic value of atrial pacing and thallium-201 scintigraphy for the assessment of patients with chest pain.

Authors:  H G Stratmann; A L Mark; K E Walter; G A Williams
Journal:  Clin Cardiol       Date:  1989-04       Impact factor: 2.882

View more
  9 in total

1.  Safety and feasibility of atropine added to submaximal exercise stress testing with Tl-201 SPECT for the diagnosis of myocardial ischemia.

Authors:  Juan Cosín-Sales; Alicia M Maceira; María J García-Velloso; Alfonso Macías; Marta Gimenez; Ignacio García-Bolao; Isabel Coma-Canella
Journal:  J Nucl Cardiol       Date:  2002 Nov-Dec       Impact factor: 5.952

2.  Return of dual-isotope SPECT myocardial perfusion imaging? Not so fast….

Authors:  Milena J Henzlova; W Lane Duvall
Journal:  J Nucl Cardiol       Date:  2015-06       Impact factor: 5.952

3.  Safer stress tests for myocardial perfusion imaging.

Authors:  Sang-Geon Cho; Zeenat Jabin; Henry Hee-Seung Bom
Journal:  J Nucl Cardiol       Date:  2017-10-16       Impact factor: 5.952

4.  Exercise supplementation to dipyridamole prevents hypotension, improves electrocardiogram sensitivity, and increases heart-to-liver activity ratio on Tc-99m sestamibi imaging.

Authors:  J V Vitola; J C Brambatti; F Caligaris; C R Lesse; P R Nogueira; A I Joaquim; M Loyo; F V Salis; E V Paiva; W A Chalela; J C Meneghetti
Journal:  J Nucl Cardiol       Date:  2001 Nov-Dec       Impact factor: 5.952

5.  Technetium 99m-labeled tetrofosmin myocardial tomography in patients with coronary artery disease: comparison between adenosine and dynamic exercise stress testing.

Authors:  A Cuocolo; E Nicolai; A Soricelli; L Pace; A Nappi; P Sullo; S Cardei; L Argenziano; P J Ell; M Salvatore
Journal:  J Nucl Cardiol       Date:  1996 May-Jun       Impact factor: 5.952

6.  One-year prognosis of patients with normal planar or single-photon emission computed tomographic technetium 99m-labeled sestamibi exercise imaging.

Authors:  K Raiker; A J Sinusas; F J Wackers; B L Zaret
Journal:  J Nucl Cardiol       Date:  1994 Sep-Oct       Impact factor: 5.952

7.  Comparison of exercise, dipyridamole, and adenosine by use of technetium 99m sestamibi tomographic imaging.

Authors:  C D Santos-Ocampo; S D Herman; M I Travin; C E Garber; A W Ahlberg; D E Messinger; G V Heller
Journal:  J Nucl Cardiol       Date:  1994 Jan-Feb       Impact factor: 5.952

8.  Comparison between exercise and trans-oesophageal atrial pacing in patients with coronary artery disease: technetium-99m methoxy isobutyl isonitrile simultaneous evaluation of ventricular function and myocardial perfusion.

Authors:  A Cuocolo; M Santomauro; L Pace; L Celentano; A Nappi; E Nicolai; M Chiariello; M Salvatore
Journal:  Eur J Nucl Med       Date:  1992

9.  Safety and feasibility of atropine added in patients with sub-maximal heart rate during exercise myocardial perfusion SPECT.

Authors:  Filippo Maria Sarullo; Corrado Ventimiglia; Andrea Taormina; Vincenzo Azzarello; Filippo Felice; Annamaria Martino; Salvatore Paterna; Pietro Di Pasquale
Journal:  Int J Cardiovasc Imaging       Date:  2006-11-16       Impact factor: 2.316

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.